Literature DB >> 12914626

Pacemaker lead infection in young patients.

Didier Klug1, Guy Vaksmann, Moustapha Jarwé, Frédéric Wallet, Charles Francart, Salem Kacet, Christian Rey.   

Abstract

Transvenous pacing has become widespread in the pediatric population, but related pacemaker lead infection in young patients has rarely been reported. To determine prevalence and optimal management of pacemaker lead infection in children and young adults, the authors reviewed their pacing database including 4476 patients who previously had pacemaker implantations from 1975 to 2001. A pacemaker was implanted in 304 patients under the age of 40. Of these patients 217 of them had congenital heart disease: 108 with structural defect, 109 without (mainly complete AV blocks). Among patients with congenital heart disease, 12 developed a pacemaker lead infection (5.5%, 6 patients with structural defect, 6 without). This incidence was significantly higher than in patients < 40 years at first implantation without congenital heart disease (2.3%) and in > 40-year-old patients(1.2%, P < 0.001). However, the number of reinterventions at the pulse generator site was higher in patients having had their first implantation before the age of 40. In patients with structural cardiac defect: two died after surgical lead extraction and one died before the scheduled lead extraction. The three remaining patients had successful surgical (n = 1) or percutaneous (n = 2) lead extractions. In patients without structural cardiac defect successful percutaneous extraction (5/6) or surgical extraction (1/6 with vegetation > 25 mm) was performed. One patient with percutaneous extraction developed chronic cor pulmonale during follow-up. One infection recurred in one patient with structural cardiac defect although complete removal of the pacing material had been performed. The prevalence of pacemaker lead infection is higher in younger patients, perhaps in part due to a higher number of procedures at the pacemaker site than in the general population of patients with a pacemaker. Patients with structural cardiac defect who underwent surgical lead removal were at high risk for death. Patients with percutaneous lead extraction may develop cor pulmonale.

Entities:  

Mesh:

Year:  2003        PMID: 12914626     DOI: 10.1046/j.1460-9592.2003.t01-1-00215.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  Antibiotic Prophylaxis Practices in Pediatric Cardiac Implantable Electronic Device Procedures: A Survey of the Pediatric And Congenital Electrophysiology Society (PACES).

Authors:  Spenser Y Chen; Scott R Ceresnak; Kara S Motonaga; Anthony Trela; Debra Hanisch; Anne M Dubin
Journal:  Pediatr Cardiol       Date:  2018-03-22       Impact factor: 1.655

2.  Comparison of modern steroid-eluting epicardial and thin transvenous pacemaker leads in pediatric and congenital heart disease patients.

Authors:  Elizabeth B Fortescue; Charles I Berul; Frank Cecchin; Edward P Walsh; John K Triedman; Mark E Alexander
Journal:  J Interv Card Electrophysiol       Date:  2005-10       Impact factor: 1.900

Review 3.  Infective endocarditis in congenital heart disease.

Authors:  Walter Knirsch; David Nadal
Journal:  Eur J Pediatr       Date:  2011-07-20       Impact factor: 3.183

Review 4.  Pacing device therapy in infants and children: a review.

Authors:  Daiji Takeuchi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-10-27       Impact factor: 1.731

Review 5.  Prevention, Diagnosis, and Treatment of Cardiac Implantable Electronic Device Infections.

Authors:  Steven Leung; Stephan Danik
Journal:  Curr Cardiol Rep       Date:  2016-06       Impact factor: 2.931

6.  Genetic identification and risk factor analysis of asymptomatic bacterial colonization on cardiovascular implantable electronic devices.

Authors:  Xian-Ming Chu; Bing Li; Yi An; Xue-Bin Li; Ji-Hong Guo
Journal:  Biomed Res Int       Date:  2014-11-02       Impact factor: 3.411

7.  Identification of bacteriology and risk factor analysis of asymptomatic bacterial colonization in pacemaker replacement patients.

Authors:  Xian-Ming Chu; Hua Yu; Xue-Xia Sun; Yi An; Bing Li; Xue-Bin Li
Journal:  PLoS One       Date:  2015-03-13       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.