Literature DB >> 29564522

Antibiotic Prophylaxis Practices in Pediatric Cardiac Implantable Electronic Device Procedures: A Survey of the Pediatric And Congenital Electrophysiology Society (PACES).

Spenser Y Chen1, Scott R Ceresnak1, Kara S Motonaga1, Anthony Trela1, Debra Hanisch1, Anne M Dubin2.   

Abstract

Cardiac implantable electronic device (CIED) infections are associated with significant morbidity in the pediatric device population, with a tenfold higher risk of infection in children compared to adults. The 2010 American Heart Association (AHA) guidelines recommend a single dose of systemic antibiotic (ABX) prophylaxis prior to CIED implantation and no post-operative (OP) ABX. However, there is limited data regarding adherence to this recommendation among the pediatric community. To assess current clinical practices for CIED ABX prophylaxis in pediatrics; whether the AHA guidelines are being followed; and if not, the reasons for non-adherence. An anonymous web-based survey was sent to physician members of the Pediatric And Congenital Electrophysiology Society regarding ABX prophylaxis for new CIED implants and reoperations. 75 (25%) members responded. Only 7% of respondents follow the 2010 AHA guidelines. While all respondents give pre-OP IV ABX, 64% routinely treat patients with 24-h post-OP IV ABX with additional oral or IV therapy. 69% of respondents are cognizant of the guidelines but 88% of those cognizant do not follow the guidelines for a variety of reasons including lack of data and different substrate (pediatric patients). 79% stated that pediatric-specific data would be required for them to change their practice and follow the published guidelines. The majority of pediatric EP physicians who responded to this survey do not follow the current AHA guidelines on ABX prophylaxis and administer post-OP ABX. Most pediatric EP physicians believe that the increased risk of infection in children merits additional ABX.

Entities:  

Keywords:  Antibiotics; Implantable device; Pediatric; Prophylaxis

Mesh:

Year:  2018        PMID: 29564522     DOI: 10.1007/s00246-018-1865-0

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  16 in total

1.  Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003.

Authors:  Andrew Voigt; Alaa Shalaby; Samir Saba
Journal:  J Am Coll Cardiol       Date:  2006-07-12       Impact factor: 24.094

2.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

3.  16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008.

Authors:  Arnold J Greenspon; Jasmine D Patel; Edmund Lau; Jorge A Ochoa; Daniel R Frisch; Reginald T Ho; Behzad B Pavri; Steven M Kurtz
Journal:  J Am Coll Cardiol       Date:  2011-08-30       Impact factor: 24.094

4.  Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings.

Authors:  M Mirowski; P R Reid; M M Mower; L Watkins; V L Gott; J F Schauble; A Langer; M S Heilman; S A Kolenik; R E Fischell; M L Weisfeldt
Journal:  N Engl J Med       Date:  1980-08-07       Impact factor: 91.245

5.  Pediatric ICD utilization in the United States from 1997 to 2006.

Authors:  Kristin M Burns; Frank Evans; Jonathan R Kaltman
Journal:  Heart Rhythm       Date:  2010-09-29       Impact factor: 6.343

6.  Pacemaker lead infection in young patients.

Authors:  Didier Klug; Guy Vaksmann; Moustapha Jarwé; Frédéric Wallet; Charles Francart; Salem Kacet; Christian Rey
Journal:  Pacing Clin Electrophysiol       Date:  2003-07       Impact factor: 1.976

7.  Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society.

Authors:  M J Silka; J Kron; A Dunnigan; M Dick
Journal:  Circulation       Date:  1993-03       Impact factor: 29.690

8.  Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.

Authors:  Larry M Baddour; Andrew E Epstein; Christopher C Erickson; Bradley P Knight; Matthew E Levison; Peter B Lockhart; Frederick A Masoudi; Eric J Okum; Walter R Wilson; Lee B Beerman; Ann F Bolger; N A Mark Estes; Michael Gewitz; Jane W Newburger; Eleanor B Schron; Kathryn A Taubert
Journal:  Circulation       Date:  2010-01-04       Impact factor: 29.690

9.  Pacemaker therapy in patients with neurally mediated syncope and documented asystole: Third International Study on Syncope of Uncertain Etiology (ISSUE-3): a randomized trial.

Authors:  Michele Brignole; Carlo Menozzi; Angel Moya; Dietrich Andresen; Jean Jacques Blanc; Andrew D Krahn; Wouter Wieling; Xulio Beiras; Jean Claude Deharo; Vitantonio Russo; Marco Tomaino; Richard Sutton
Journal:  Circulation       Date:  2012-05-07       Impact factor: 29.690

10.  Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis.

Authors:  Chunliu Zhan; William B Baine; Artyom Sedrakyan; Claudia Steiner
Journal:  J Gen Intern Med       Date:  2008-01       Impact factor: 5.128

View more
  3 in total

1.  Peri-Operative Prophylaxis in Patients of Neonatal and Pediatric Age Subjected to Cardiac and Thoracic Surgery: A RAND/UCLA Appropriateness Method Consensus Study.

Authors:  Sonia Bianchini; Laura Nicoletti; Sara Monaco; Erika Rigotti; Agnese Corbelli; Annamaria Colombari; Cinzia Auriti; Caterina Caminiti; Giorgio Conti; Maia De Luca; Daniele Donà; Luisa Galli; Silvia Garazzino; Alessandro Inserra; Stefania La Grutta; Laura Lancella; Mario Lima; Andrea Lo Vecchio; Gloria Pelizzo; Nicola Petrosillo; Giorgio Piacentini; Carlo Pietrasanta; Nicola Principi; Matteo Puntoni; Alessandro Simonini; Simonetta Tesoro; Elisabetta Venturini; Annamaria Staiano; Fabio Caramelli; Gaetano Domenico Gargiulo; Susanna Esposito
Journal:  Antibiotics (Basel)       Date:  2022-04-21

2.  Surveillance Cultures and Infection in 230 Pacemaker and Defibrillator Generator Changes in Pediatric and Adult Congenital Patients.

Authors:  Gregory Webster; Lauren C Balmert; Ami B Patel; Larry K Kociolek; Melanie Gevitz; Rachael Olson; Ahmed S Chaouki; Osama El-Tayeb; Michael C Monge; Carl Backer
Journal:  World J Pediatr Congenit Heart Surg       Date:  2021-05

3.  Factors that influence adherence to surgical antimicrobial prophylaxis (SAP) guidelines: a systematic review.

Authors:  Sarah Hassan; Vincent Chan; Julie Stevens; Ieva Stupans
Journal:  Syst Rev       Date:  2021-01-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.