Retrieval analyses of a blade implant after 231 months of clinical function.

L I Linkow1, K Donath, J E Lemons.   

Abstract

A blade implant that was retrieved in 1990 after 231 months of clinical function (since 1971) was analyzed with respect to clinical, histological, and biomechanical characteristics. The implant clinical records demonstrated no abnormalities or pathological lesions over the tenure of treatment. The bone to implant interface showed a mixture of interfacial tissue components and conditions with adequate direct bone contact (46.4 to 82.3 percent) for classification as osseointegrated. The abutment fracture leading to removal was characterized as a cyclic fatigue mechanism and the distribution of tissue components along the interface could not be correlated with specific biomechanical loading directions. This report considers the clinical and biomechanical records as they relate to the detailed histological investigation.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1288796

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  6 in total

1.  Custom-made, selective laser sintering (SLS) blade implants as a non-conventional solution for the prosthetic rehabilitation of extremely atrophied posterior mandible.

Authors:  F Mangano; M Bazzoli; L Tettamanti; D Farronato; M Maineri; A Macchi; C Mangano
Journal:  Lasers Med Sci       Date:  2012-09-14       Impact factor: 3.161

2.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

3.  A clinico radiographic study of immediate loading implants in rehabilitation of mandibular ridges.

Authors:  M Viswambaran; Vimal Arora; S H Gupta; R K Dhiman; N Thiruvalluvan
Journal:  Med J Armed Forces India       Date:  2014-08-22

4.  Mathematical modeling and mechanical and histopathological testing of porous prosthetic pylon for direct skeletal attachment.

Authors:  Mark Pitkin; Grigory Raykhtsaum; John Pilling; Yuri Shukeylo; Vladimir Moxson; Volodimir Duz; John Lewandowski; Raymond Connolly; Robert S Kistenberg; John F Dalton; Boris Prilutsky; Stewart Jacobson
Journal:  J Rehabil Res Dev       Date:  2009

5.  On the way to total integration of prosthetic pylon with residuum.

Authors:  Mark Pitkin
Journal:  J Rehabil Res Dev       Date:  2009

6.  Effect of loading frequency on cyclic fatigue lifetime of a standard-diameter implant with an internal abutment connection.

Authors:  Yuanyuan Duan; Jason A Griggs
Journal:  Dent Mater       Date:  2018-09-13       Impact factor: 5.304

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.