Literature DB >> 12885182

Biasing effect of the electromyogram on BIS: a controlled study during high-dose fentanyl induction.

Maurizio Renna1, Tim Wigmore, Ali Mofeez, Charles Gillbe.   

Abstract

OBJECTIVE: A biasing effect of the electromyogram (EMG) on the Bispectral Index (BIS) may explain discrepancies in previous studies assessing BIS in the presence of neuromuscular activity. Our aims were: to evaluate variations of BIS in the presence of high EMG activity associated with muscular rigidity after administration of high-dose fentanyl; to compare muscular rigidity, as measured by the EMG variable of the BIS monitor, in patients who were administered two different dosages of fentanyl at induction of cardiac anaesthesia.
METHODS: 26 patients undergoing CABG surgery, after premedication with morphine 0.15 mg/kg, were randomized to receive either fentanyl 50 mcg/kg (group F) or fentanyl 10 mcg/kg plus etomidate 0.2 mg/kg (group EF). The induction dose was administered over 2 minutes. Patients were manually ventilated with O2 via face mask. Five minutes after induction was complete, patients were clinically assessed using the Responsiveness portion of the Observer's Assessment of Alertness/Sedation scale (OAAS). Haemodynamic data were recorded and arterial blood samples obtained at the time of OAAS observation. Patients were administered a neuromuscular blocking agent only after the OAAS assessment. BIS (3.4) was recorded from an A-2000 EEG monitor (Aspect Medical Systems) using disposable sensors (BIS Sensor, Aspect Medical Systems) applied per manufacturer's instructions. Data were recorded on a PC for off-line analysis.
RESULTS: At the time of OAAS observation, mean (95% CI) BIS in group F was 85 (77-92) compared to 67 (56-79) in group EF (p = 0.01). Similarly, mean (95% CI) EMG was 50 dB (45-56) in F and 41 dB (35-47) in EF (p = 0.01). Correlation between BIS and EMG was very high (r2 = 0.88). OAAS scores were significantly higher in group F (p = 0.03). Non significant correlation was observed between BIS and OAAS scores (r2 = 0.32, p = 0.1). Backward stepwise multiple regression analysis including EMG, pH, CO2, O2 and OASS scores showed EMG as strong predictor of BIS (p < 0.0001, r2 = 0.7). Regression of EMG against BIS yielded the equation: BIS = 3.7 + (1.6 x EMG).
CONCLUSION: During fentanyl-induced muscular rigidity BIS recordings reflect EMG variations. When assessing BIS in the absence of neuromuscular blockade, it is necessary to evaluate the effect of EMG on BIS before making conclusions about depth of sedation. Fentanyl-induced rigidity appears to be a dose-related phenomenon which the EMG variable of BIS 3.4 is able to quantify.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12885182     DOI: 10.1023/a:1024210405543

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  15 in total

1.  Electromyographic activity falsely elevates the bispectral index.

Authors:  J Bruhn; T W Bouillon; S L Shafer
Journal:  Anesthesiology       Date:  2000-05       Impact factor: 7.892

2.  Effects on the bispectral index during medium-high dose fentanyl induction with or without propofol supplement.

Authors:  G Barr; R E Anderson; A Owall; J G Jakobsson
Journal:  Acta Anaesthesiol Scand       Date:  2000-08       Impact factor: 2.105

Review 3.  A primer for EEG signal processing in anesthesia.

Authors:  I J Rampil
Journal:  Anesthesiology       Date:  1998-10       Impact factor: 7.892

4.  Is the bispectral index appropriate for monitoring the sedation level of mechanically ventilated surgical ICU patients?

Authors:  Dirk Frenzel; Clemens-A Greim; Christian Sommer; Kerstin Bauerle; Norbert Roewer
Journal:  Intensive Care Med       Date:  2002-01-12       Impact factor: 17.440

5.  Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers.

Authors:  P S Glass; M Bloom; L Kearse; C Rosow; P Sebel; P Manberg
Journal:  Anesthesiology       Date:  1997-04       Impact factor: 7.892

6.  Titration of isoflurane using BIS index improves early recovery of elderly patients undergoing orthopedic surgeries.

Authors:  Jean Wong; Dajun Song; Hannah Blanshard; Deidre Grady; Frances Chung
Journal:  Can J Anaesth       Date:  2002-01       Impact factor: 5.063

7.  Anesthetic induction with fentanyl.

Authors:  P L Bailey; J Wilbrink; P Zwanikken; N L Pace; T H Stanley
Journal:  Anesth Analg       Date:  1985-01       Impact factor: 5.108

8.  Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation Scale.

Authors:  L E Simmons; R R Riker; B S Prato; G L Fraser
Journal:  Crit Care Med       Date:  1999-08       Impact factor: 7.598

9.  A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect.

Authors:  P S Sebel; E Lang; I J Rampil; P F White; R Cork; M Jopling; N T Smith; P S Glass; P Manberg
Journal:  Anesth Analg       Date:  1997-04       Impact factor: 5.108

10.  Reducing myoclonus after etomidate.

Authors:  A W Doenicke; M F Roizen; J Kugler; H Kroll; J Foss; P Ostwald
Journal:  Anesthesiology       Date:  1999-01       Impact factor: 7.892

View more
  9 in total

1.  Response entropy changes after noxius stimulus.

Authors:  Jose L Guerrero; E Matute; E Alsina; B Del Blanco; F Gilsanz
Journal:  J Clin Monit Comput       Date:  2012-03-20       Impact factor: 2.502

Review 2.  Using EEG to monitor anesthesia drug effects during surgery.

Authors:  Leslie C Jameson; Tod B Sloan
Journal:  J Clin Monit Comput       Date:  2006-12       Impact factor: 2.502

3.  BIS monitor findings during self-hypnosis.

Authors:  Christopher M Burkle; Christopher J Jankowski; Laurence C Torsher; Edwin H Rho; Amy C Degnim
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

4.  Comparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients.

Authors:  Carmen Hernández-Gancedo; David Pestaña; Hanna Pérez-Chrzanowska; Elena Martinez-Casanova; Antonio Criado
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

5.  Response entropy is more reactive than bispectral index during laparoscopic gastric banding.

Authors:  James Feld; William E Hoffman
Journal:  J Clin Monit Comput       Date:  2006-07-04       Impact factor: 2.502

6.  The effects of the extent of spinal block on the BIS score and regional cerebral oxygen saturation in elderly patients: A prospective, randomized, and double-blinded study.

Authors:  Koichi Nishikawa; Ryuji Hagiwara; Kohji Nakamura; Junko Ishizeki; Kazuhiro Kubo; Shigeru Saito; Fumio Goto
Journal:  J Clin Monit Comput       Date:  2007-01-10       Impact factor: 2.502

7.  The utility of bispectral index monitoring for sedated patients treated with low-dose remifentanil.

Authors:  Takao Kato; Toshiya Koitabashi; Takashi Ouchi; Ryohei Serita
Journal:  J Clin Monit Comput       Date:  2012-07-25       Impact factor: 2.502

8.  Recovery from paralysis with succinylcholine increased Response entropy and EMG but not State entropy.

Authors:  Verna L Baughman; William E Hoffman; Heidi M Koenig; Peggy L Wheeler; Ranga C Ananda; Mathew Wang
Journal:  J Clin Monit Comput       Date:  2005-06       Impact factor: 2.502

Review 9.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.