Literature DB >> 10939694

Effects on the bispectral index during medium-high dose fentanyl induction with or without propofol supplement.

G Barr1, R E Anderson, A Owall, J G Jakobsson.   

Abstract

BACKGROUND: The search for a drug-independent monitor to determine depth of anaesthesia and hypnosis continues. The bispectral analysis (BIS) of the EEG correlates well with the clinical dose-response of hypnotic drugs during induction, but the effect on BIS of an opiate induction, as for coronary bypass surgery, is not known.
METHODS: Fourteen patients scheduled for elective coronary bypass surgery were studied. BIS was recorded during induction in 7 patients receiving 10 microg/kg fentanyl without any hypnotic agent and in 7 patients receiving 0.5 mg/kg propofol before the fentanyl dose.
RESULTS: The effect of fentanyl was very variable both regarding BIS and clinical response. Five of the 7 patients that received only fentanyl lost their response to verbal command within 8 min. BIS values at loss of response varied between 45 and 94. One patient remained awake with BIS 43. All 7 patients receiving propofol before the fentanyl dose lost their response to verbal command within 5 min. BIS values at the time for loss of response varied between 78 and 98.
CONCLUSION: Loss of response to verbal command when a medium-high dose of fentanyl is used for induction cannot be distinguished from wakefulness with adequate sensitivity by BIS. The current BIS algorithm seems not to accurately reflect the hypnotic effects of fentanyl.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10939694     DOI: 10.1034/j.1399-6576.2000.440707.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  4 in total

1.  Cerebral state index versus bispectral index during propofol-fentanyl-nitrous oxide anesthesia.

Authors:  Tomoki Nishiyama; Kyoko Komatsu
Journal:  J Anesth       Date:  2010-03-26       Impact factor: 2.078

Review 2.  Using EEG to monitor anesthesia drug effects during surgery.

Authors:  Leslie C Jameson; Tod B Sloan
Journal:  J Clin Monit Comput       Date:  2006-12       Impact factor: 2.502

3.  Biasing effect of the electromyogram on BIS: a controlled study during high-dose fentanyl induction.

Authors:  Maurizio Renna; Tim Wigmore; Ali Mofeez; Charles Gillbe
Journal:  J Clin Monit Comput       Date:  2002-08       Impact factor: 2.502

4.  Prospective study comparing skin impedance with EEG parameters during the induction of anaesthesia with fentanyl and etomidate.

Authors:  Michael Winterhalter; S Münte; M Gerhard; O Danzeisen; T Jüttner; E Monaca; L Hoy; N Rahe-Meyer; P Kienbaum
Journal:  Eur J Med Res       Date:  2010-02-26       Impact factor: 2.175

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.