Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer.

Rakesh R Patel1, Nigel Orton, Wolfgang A Tomé, Rick Chappell, Mark A Ritter.   

Abstract

BACKGROUND AND
PURPOSE: To compare the rectal wall and bladder volume in the high dose region with or without the use of a balloon catheter with both three-dimensional (3D)-conformal and intensity modulated radiation therapy (CRT, IMRT) approaches in the treatment of prostate cancer.
MATERIAL AND METHODS: Five patients with a wide range of prostate volumes and treated with primary external beam radiation therapy for localized prostate cancer were selected for analysis. Pinnacle treatment plans were generated utilizing a 3D conformal six-field design and an IMRT seven coplanar-field plan with a novel, three-step optimization and with ultrasound localization. Separate plans were devised with a rectal balloon deflated or air inflated with and without inclusion of the seminal vesicles (SV) in the target volume. The prescription dose was 76Gy in 38 fractions of 2Gy each. Cumulative dose-volume histograms (DVHs) were analyzed for the planning target volume (PTV), rectal wall, and bladder with an inflated (60cc air) or deflated balloon with and without SV included. The volumes of rectal wall and bladder above 60, 65, and 70Gy with each treatment approach were evaluated.
RESULTS: Daily balloon placement was well-tolerated with good patient positional reproducibility. Inflation of the rectal balloon in all cases resulted in a significant decrease in the absolute volume of rectal wall receiving greater than 60, 65, or 70Gy. The rectal sparing ratio (RSR), consisting of a structure's high dose volume with the catheter inflated, divided by the volume with the catheter deflated, was calculated for each patient with and without seminal vesicle inclusion for 3D-CRT and IMRT. For 3D-CRT, RSRs with SV included were 0.59, 0.59, and 0.56 and with SV excluded were 0.60, 0.58, and 0.54 at doses of greater than 60, 65, and 70Gy, respectively. Similarly, for IMRT, the mean RSRs were 0.59, 0.59, and 0.63 including SV and 0.71, 0.66, and 0.67 excluding SV at these same dose levels, respectively. Averaged over all conditions, inflation of the rectal balloon resulted in a significant reduction in rectal volume receiving > or =65Gy to a mean ratio of 0.61 (P=0.01) or, in other words, a mean fractional high dose rectal sparing of 39%. There was a slight overall increase to 1.13 in the relative volume of bladder receiving at least 65Gy; however, this was not significant (P=0.6). Use of an endorectal balloon with a non-image-guided 3D-CRT plan produced about as much rectal dose sparing as a highly conformal, image-guided IMRT approach without a balloon. However, inclusion of a balloon with IMRT produced further rectal sparing still.
CONCLUSION: These results indicate that use of a rectal balloon with a 3D-CRT plan incorporating typical treatment margins will produce significant high dose rectal sparing that is comparable to that achieved by a highly conformal IMRT with ultrasound localization. Further sparing is achieved with the inclusion of a balloon catheter in an IMRT plan. Thus, in addition to a previously reported advantage of prostate immobilization, the use of a rectal displacement balloon during daily treatment results in high dose rectal wall sparing during both modestly and highly conformal radiotherapy. Such sparing could assist in controlling and limiting rectal toxicity during increasingly aggressive dose escalation.

Entities:  

Mesh:

Year:  2003        PMID: 12865176     DOI: 10.1016/s0167-8140(03)00056-2

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  26 in total

1.  Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer.

Authors:  Kenji Takayama; Takashi Mizowaki; Yoshiharu Negoro; Yoshiki Norihisa; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2010-10-05       Impact factor: 3.402

2.  Image-Guided High-Dose Rate Brachytherapy in Cervix Carcinoma Using Balloon Catheter and Belt Immobilization System.

Authors:  Qiyong Fan; Anamaria R Yeung; Robert Amdur; Richard Helmig; Justin Park; Jonathan Li; Darren Kahler; Chihray Liu; Bo Lu
Journal:  Technol Cancer Res Treat       Date:  2016-02-10

3.  3-D Conformal radiotherapy of localized prostate cancer within an Austrian-German multicenter trial: a prospective study of patients' acceptance of the rectal balloon during treatment.

Authors:  Gregor Goldner; Hans Geinitz; Stefan Wachter; Gerd Becker; Frank Zimmermann; Natascha Wachter-Gerstner; Stefan Glocker; Regina Pötzi; Andre Wambersie; Michael Bamberg; Michael Molls; Horst Feldmann; Richard Pötter
Journal:  Wien Klin Wochenschr       Date:  2006-05       Impact factor: 1.704

4.  On the impact of functional imaging accuracy on selective boosting IMRT.

Authors:  Y Kim; W A Tomé
Journal:  Phys Med       Date:  2008-01-18       Impact factor: 2.685

5.  Changes in rectal volume and prostate localization due to placement of a rectum-emptying tube.

Authors:  Hiroshi Fuji; Shigeyuki Murayama; Masashi Niwakawa; Raizou Yamaguchi; Ryou Yamashita; Takashi Matsui; Haruo Yamashita; Tetsuo Nishimura; Kenichi Tobisu
Journal:  Jpn J Radiol       Date:  2009-06-25       Impact factor: 2.374

6.  In vivo real-time rectal wall dosimetry for prostate radiotherapy.

Authors:  Nicholas Hardcastle; Dean L Cutajar; Peter E Metcalfe; Michael L F Lerch; Vladimir L Perevertaylo; Wolfgang A Tomé; Anatoly B Rosenfeld
Journal:  Phys Med Biol       Date:  2010-07-07       Impact factor: 3.609

7.  Comparing photon and proton-based hypofractioned SBRT for prostate cancer accounting for robustness and realistic treatment deliverability.

Authors:  Lee C Goddard; N Patrik Brodin; William R Bodner; Madhur K Garg; Wolfgang A Tomé
Journal:  Br J Radiol       Date:  2018-03-02       Impact factor: 3.039

Review 8.  Reducing rectal injury during external beam radiotherapy for prostate cancer.

Authors:  Riccardo Valdagni; Tiziana Rancati
Journal:  Nat Rev Urol       Date:  2013-05-14       Impact factor: 14.432

9.  Endo-rectal balloon cavity dosimetry in a phantom: performance under IMRT and helical tomotherapy beams.

Authors:  Nicholas Hardcastle; Peter E Metcalfe; Anatoly B Rosenfeld; Wolfgang A Tomé
Journal:  Radiother Oncol       Date:  2009-03-30       Impact factor: 6.280

10.  Positional reproducibility and effects of a rectal balloon in prostate cancer radiotherapy.

Authors:  Jae Ho Cho; Chang-Geol Lee; Dae Ryong Kang; Jooho Kim; Sangkyu Lee; Chang-Ok Suh; Jinsil Seong; Yang Gun Suh; Ikjae Lee; Gwi Eon Kim
Journal:  J Korean Med Sci       Date:  2009-09-24       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.