Literature DB >> 12857707

Factors influencing fluoroscopy time and dose-area product values during ad hoc one-vessel percutaneous coronary angioplasty.

F Larrazet1, A Dibie, F Philippe, R Palau, R Klausz, F Laborde.   

Abstract

X-ray exposure during radiologically guided interventional procedures may have some deleterious effects. The aim of our study was to analyse the factors affecting patient dose during percutaneous coronary angioplasty (PTCA). We evaluated radiation dose during coronary angiography followed by one-vessel PTCA in 402 consecutive patients who were treated by three experienced physicians using both femoral and radial techniques. Fluoroscopy time (t) and patient dose measured by a dose-area product (DAP) meter were recorded. A good correlation was observed between t and the DAP (r=0.78, p<0.001). To assess the factors affecting radiation exposure, we studied the differences between operators, arterial catheterization access and stenting strategy. Median (25th to 75th percentiles) values for t were 19 (13 to 26) min and for DAP were 191 (145 to 256) Gy cm(2) for operator 3 compared with t=12 (9 to 18) min and DAP=137 (91 to 208) Gy cm(2) for operator 2 (p<0.005 versus operator 3) and t=13 (9 to 17) min, and DAP=134 (93 to 190) Gy cm(2) for operator 1 (p<0.001 versus operator 3). Differences between the radial and the femoral techniques were: t=17 (13 to 24) min versus 12 (8 to 17) min, (p<0.001) and DAP=175 (128 to 246) Gy cm(2) versus 138 (93 to 197) Gy cm(2), (p<0.001). In comparison with stenting without pre-dilation, direct stenting significantly reduced t and DAP [t=12 (9 to 16) min versus 16 (11 to 22) min, (p<0.001) and DAP=130 (95 to 186) Gy cm(2) versus 163 (119 to 230) Gy cm(2), respectively, (p<0.01)]. Radiation exposure to patients and staff are strongly dependent on operators, stenting strategy and the arterial access chosen for ad hoc one-vessel PTCA.

Entities:  

Mesh:

Year:  2003        PMID: 12857707     DOI: 10.1259/bjr/21553230

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

Review 1.  Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review.

Authors:  Kwang Pyo Kim; Donald L Miller
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

2.  Radiation exposure in children during the current era of pediatric cardiac intervention.

Authors:  Maiy Hamdy El Sayed; Alaa Mahmoud Roushdy; Hala El Farghaly; Ahmad El Sherbini
Journal:  Pediatr Cardiol       Date:  2011-08-03       Impact factor: 1.655

3.  Radiation-reducing planning of cardiac catheterisation.

Authors:  E Kuon; J B Dahm; D M Robinson; K Empen; M Günther; W Wucherer
Journal:  Z Kardiol       Date:  2005-10

4.  Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access.

Authors:  Håkan Geijer; Jan Persliden
Journal:  Eur Radiol       Date:  2004-04-21       Impact factor: 5.315

5.  Radiation-induced noncancer risks in interventional cardiology: optimisation of procedures and staff and patient dose reduction.

Authors:  Zhonghua Sun; Aini AbAziz; Ahmad Khairuddin Md Yusof
Journal:  Biomed Res Int       Date:  2013-08-20       Impact factor: 3.411

6.  Comparison of the patient radiation exposure during coronary angiography and angioplasty procedures using trans-radial and trans-femoral access.

Authors:  Ali Tarighatnia; Amir Hossein Mohammad Alian; Morteza Ghojazadeh; Alir Reza Farajollahi
Journal:  J Cardiovasc Thorac Res       Date:  2016-06-28

7.  Establishing a diagnostic reference level of radiation dose in coronary angiography and intervention: A prospective evaluation.

Authors:  Vikas Kataria; Ishita Yaduvanshi; Gautam Singal; Mohan Nair
Journal:  Indian Heart J       Date:  2021-09-21

8.  Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals.

Authors:  James A Crowhurst; Mark Whitby; David Thiele; Toni Halligan; Adam Westerink; Suzanne Crown; Jillian Milne
Journal:  J Med Radiat Sci       Date:  2014-08-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.