Literature DB >> 12852552

MAGIC-type polymer gel for three-dimensional dosimetry: intensity-modulated radiation therapy verification.

Helen Gustavsson1, Anna Karlsson, Sven A J Bäck, Lars E Olsson, Pia Haraldsson, Per Engström, Håkan Nyström.   

Abstract

A new type of polymer gel dosimeter, which responds well to absorbed dose even when manufactured in the presence of normal levels of oxygen, was recently described by Fong et al. [Phys. Med. Biol. 46, 3105-3113 (2001)] and referred to by the acronym MAGIC. The aim of this study was to investigate the feasibility of using this new type of gel for intensity-modulated radiation therapy (IMRT) verification. Gel manufacturing was carried out in room atmosphere under normal levels of oxygen. IMRT inverse treatment planning was performed using the Helios software. The gel was irradiated using a linear accelerator equipped with a dynamic multileaf collimator, and intensity modulation was achieved using sliding window technique. The response to absorbed dose was evaluated using magnetic resonance imaging. Measured and calculated dose distributions were compared with regard to in-plane isodoses and dose volume histograms. In addition, the spatial and dosimetric accuracy was evaluated using the gamma formalism. Good agreement between calculated and measured data was obtained. In the isocenter plane, the 70% and 90% isodoses acquired using the different methods are mostly within 2 mm, with up to 3 mm disagreement at isolated points. For the planning target volume (PTV), the calculated mean relative dose was 96.8 +/- 2.5% (1 SD) and the measured relative mean dose was 98.6 +/- 2.2%. Corresponding data for an organ at risk was 34.4 +/- 0.9% and 32.7 +/- 0.7%, respectively. The gamma criterion (3 mm spatial/3% dose deviation) was fulfilled for 94% of the pixels in the target region. Discrepancies were found in hot spots the upper and lower parts of the PTV, where the measured dose was up to 11% higher than calculated. This was attributed to sub optimal scatter kernels used in the treatment planning system dose calculations. Our results indicate great potential for IMRT verification using MAGIC-type polymer gel.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12852552     DOI: 10.1118/1.1576392

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Commissioning and benchmarking a 3D dosimetry system for clinical use.

Authors:  Andrew Thomas; Joseph Newton; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

2.  Initial characterization of a gel patch dosimeter for in vivo dosimetry.

Authors:  C Matrosic; W Culberson; B Rosen; E Madsen; G Frank; B Bednarz
Journal:  Phys Med Biol       Date:  2016-04-18       Impact factor: 3.609

Review 3.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

4.  Development and validation of MCNPX-based Monte Carlo treatment plan verification system.

Authors:  Iraj Jabbari; Shahram Monadi
Journal:  J Med Phys       Date:  2015 Apr-Jun

5.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

6.  Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.

Authors:  Vladimir Feygelman; Geoffrey Zhang; Craig Stevens; Benjamin E Nelms
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

7.  Uncertainty Analysis in MRI-based Polymer Gel Dosimetry.

Authors:  M Keshtkar; M H Zahmatkesh; A R Montazerabadi
Journal:  J Biomed Phys Eng       Date:  2017-09-01

8.  Three-dimensional polymer gel dosimetry using an onboard 0.35 T magnetic resonance imaging scanner: A simulation study.

Authors:  Lei Zhang; Yanle Hu; Dongsu Du; Olga L Green; H Omar Wooten; H Harold Li
Journal:  J Med Phys       Date:  2015 Jul-Sep

9.  Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT.

Authors:  Vladimir Feygelman; Kenneth Forster; Daniel Opp; Görgen Nilsson
Journal:  J Appl Clin Med Phys       Date:  2009-09-30       Impact factor: 2.102

10.  MAGIC polymer gel for dosimetric verification in boron neutron capture therapy.

Authors:  Jouni Uusi-Simola; Sami Heikkinen; Petri Kotiluoto; Tom Serén; Tiina Seppälä; Iiro Auterinen; Sauli Savolainen
Journal:  J Appl Clin Med Phys       Date:  2007-04-30       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.