Literature DB >> 12838221

Prospective, randomized, single-center trial comparing 3 different 10F plastic stents in malignant mid and distal bile duct strictures.

Dieter Schilling1, Günter Rink, Joachim C Arnold, Claus Benz, Henning E Adamek, Ralf Jakobs, Jürgen F Riemann.   

Abstract

BACKGROUND: The aim of this study was to determine whether patency rates differ with respect to the material, design, and surface texture of 3 different plastic stents.
METHODS: A total of 120 patients (median age 70.5 years; interquartile range 62-78 years) with malignant mid or distal bile duct strictures, seen between March 1996 and May 1999, were prospectively randomized to receive a 10F polyurethane stent, a Teflon Tannenbaum stent, or a hydrophilic hydromer-coated polyurethane stent. The primary study outcome measure was the interval between stent insertion and the first episode of clogging (or the presence of jaundice at death without stent exchange). All 3 types of stent were studied by scanning electron microscopy before insertion.
RESULTS: A total of 19 patients were excluded from long-term follow-up. Median duration of stent patency was 76 days overall (interquartile range 29-150 days) and 76 (interquartile range 30-110) days for hydrophilic hydromer-coated polyurethane, 108 (interquartile range 33-186) days for 10F polyurethane, and 58 (interquartile range 21-188) days for Teflon Tannenbaum stents. There were no statistically significant differences among stent types. The hydrophilic hydromer-coated stent had the smoothest surface, as visualized by scanning electron microscopy.
CONCLUSIONS: No significant differences in the patency of 3 types of stents were detected in this randomized trial. In particular, the hydrophilic hydromer-coated plastic stent did not provide clinical advantages despite its smooth surface.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12838221     DOI: 10.1067/mge.2003.319

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  10 in total

Review 1.  Endoscopic papillotomy, syn. sphincterotomy: results from the past two years.

Authors:  Meinhard Classen; Peter Born
Journal:  Curr Gastroenterol Rep       Date:  2004-04

Review 2.  Antireflux biliary stents: are they the solution to stent occlusions?

Authors:  D Nageshwar Reddy; Rupa Banerjee; Ong Wai Choung
Journal:  Curr Gastroenterol Rep       Date:  2006-04

3.  Tannenbaum and metal stents in the palliative treatment of malignant distal bile duct obstruction: a comparative study of patency and cost effectiveness.

Authors:  P Katsinelos; D Paikos; J Kountouras; G Chatzimavroudis; G Paroutoglou; I Moschos; A Gatopoulou; A Beltsis; C Zavos; B Papaziogas
Journal:  Surg Endosc       Date:  2006-08-07       Impact factor: 4.584

4.  A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

Authors:  Mouen A Khashab; Susan Hutfless; Katherine Kim; Anne Marie Lennon; Marcia I Canto; Sanjay B Jagannath; Patrick I Okolo; Eun Ji Shin; Vikesh K Singh
Journal:  Dig Dis Sci       Date:  2012-01-20       Impact factor: 3.199

5.  Time Sequence Evaluation of Biliary Stent Occlusion by Dissection Analysis of Retrieved Stents.

Authors:  Chang-Il Kwon; Mark A Gromski; Stuart Sherman; Jeffrey J Easler; Ihab I El Hajj; James Watkins; Evan L Fogel; Lee McHenry; Glen A Lehman
Journal:  Dig Dis Sci       Date:  2016-05-06       Impact factor: 3.199

6.  Endoscopic stent placement above the intact sphincter of Oddi for biliary strictures after living donor liver transplantation.

Authors:  Akira Kurita; Yuzo Kodama; Ryuki Minami; Yojiro Sakuma; Katsutoshi Kuriyama; Wataru Tanabe; Yuji Ohta; Takahisa Maruno; Masahiro Shiokawa; Yugo Sawai; Norimitsu Uza; Shujiro Yazumi; Atsushi Yoshizawa; Shinji Uemoto; Tsutomu Chiba
Journal:  J Gastroenterol       Date:  2013-01-17       Impact factor: 7.527

7.  Permanent stenting in "unextractable" common bile duct stones in high risk patients. A prospective randomized study comparing two different stents.

Authors:  Franco Pisello; Girolamo Geraci; Francesco Li Volsi; Giuseppe Modica; Carmelo Sciumè
Journal:  Langenbecks Arch Surg       Date:  2008-08-05       Impact factor: 3.445

Review 8.  Palliative biliary stents for obstructing pancreatic carcinoma.

Authors:  A C Moss; E Morris; P Mac Mathuna
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

9.  Efficacy of the new double-layer stent for unresectable distal malignant biliary obstruction: a single-center retrospective study.

Authors:  Ken Ito; Yoshinori Igarashi; Takahiko Mimura; Yui Kishimoto; Yoshinori Kikuchi; Naoki Okano
Journal:  Diagn Ther Endosc       Date:  2012-03-07

10.  Stenting and interventional radiology for obstructive jaundice in patients with unresectable biliary tract carcinomas.

Authors:  Toshio Tsuyuguchi; Tadahiro Takada; Masaru Miyazaki; Shuichi Miyakawa; Kazuhiro Tsukada; Masato Nagino; Satoshi Kondo; Junji Furuse; Hiroya Saito; Masafumi Suyama; Fumio Kimura; Hideyuki Yoshitomi; Satoshi Nozawa; Masahiro Yoshida; Keita Wada; Hodaka Amano; Fumihiko Miura
Journal:  J Hepatobiliary Pancreat Surg       Date:  2008-02-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.