Image quality of two solid-state and three photostimulable phosphor plate digital panoramic systems, and treatment planning of mandibular third molar removal.

I S Benediktsdottir1, H Hintze, J K Petersen, A Wenzel.   

Abstract

OBJECTIVES: The purpose was to evaluate image quality of two solid-state (charge-coupled device (CCD)) and three photostimulable phosphor (PSP) plate digital panoramic systems, and to assess their utility for treatment planning before mandibular third molar removal.
METHODS: 433 patients were randomly allocated to five digital systems: Dimax2 and Orthophos Plus (both CCD systems) and DenOptix, DigiDent and Digora (all PSP systems). Image quality was evaluated in six regions on a 4-point scale by three independent observers. In addition, an oral surgeon evaluated image quality in the mandibular third molar region only as well as the utility of the image for treatment planning before removal of that molar.
RESULTS: Images from the DenOptix and DigiDent systems had a significantly lower overall quality than images from the Digora, Dimax2 and Orthophos Plus systems (P < 0.005). The oral surgeon's assessment of image utility resulted in rejection rates of 0% for Orthophos Plus, 2% for Digora, 8% for Dimax2, 12% for DigiDent and 14% for DenOptix images. The rates for the DigiDent and DenOptix images were significantly higher than those for the other systems (P < 0.001), and the rate for Dimax2 was significantly higher than that for Orthophos Plus (P = 0.002).
CONCLUSIONS: The quality of DenOptix and DigiDent digital panoramic images was found to be inferior to the quality found in images obtained with the Digora, Dimax2 and Orthophos Plus systems. Images from the Digora and Orthophos Plus systems were regarded to be the most useful for treatment planning before mandibular third molar removal.

Entities:  

Mesh:

Year:  2003        PMID: 12820852     DOI: 10.1259/dmfr/25838744

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  8 in total

1.  Subjective image quality of digital panoramic radiographs displayed on monitor and printed on various hardcopy media.

Authors:  Frieda Gijbels; Gerard Sanderink; Herman Pauwels; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2003-12-02       Impact factor: 3.573

2.  Perception of anatomical structures in digitally filtered and conventional panoramic radiographs: a clinical evaluation.

Authors:  B G Baksi; E Alpöz; E Sogur; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

Review 3.  Preoperative imaging procedures for lower wisdom teeth removal.

Authors:  Lennart Flygare; Anders Ohman
Journal:  Clin Oral Investig       Date:  2008-04-30       Impact factor: 3.573

4.  Image quality assessment in panoramic dental radiography: a comparative study between conventional and digital systems.

Authors:  Akmal Sabarudin; Yu Jin Tiau
Journal:  Quant Imaging Med Surg       Date:  2013-02

5.  Accuracy of scanography using storage phosphor plate systems and film for assessment of mandibular third molars.

Authors:  L H Matzen; J Christensen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

6.  Development of a new dental panoramic radiographic system based on a tomosynthesis method.

Authors:  K Ogawa; R P Langlais; W D McDavid; M Noujeim; K Seki; T Okano; T Yamakawa; T Sue
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

7.  The effects of image acquisition control of digital X-ray system on radiodensity quantification.

Authors:  Wook-Jin Seong; Hyeon-Cheol Kim; Soocheol Jeong; Youngcheul Heo; Woo-Bin Song; Mansur Ahmad
Journal:  Restor Dent Endod       Date:  2013-08-23

8.  Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study.

Authors:  Mohammad Mahdi Yaghooti Khorasani; Hamed Ebrahimnejad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20