METHODS: 48 consecutive elderly patients had 60 NexGen Legacy posterior-stabilised total knees. The mean follow-up duration was 21 months. Clinical evaluation was performed according to the Knee Society scores and a scoring system for patellofemoral articulation; radiographic assessment followed the guidelines of the Knee Society. Special emphasis was given to any patellofemoral complications, such as patellar clunk syndrome, patellar maltracking, and other disorders of the extensor mechanism.
RESULTS: Only one patient had mild patellofemoral anterior knee pain at the latest follow-up; 2 patients had patellofemoral crepitus but no pain. No patellar clunk or any other complication of the patellofemoral articulation, such as patellar fracture or subluxation was found. The mean preoperative and postoperative Knee Society scores were 60 and 85 respectively. The mean postoperative knee flexion was 115 degrees.
CONCLUSION: The overall early results from using the new implant were good, probably because of changes in design of the intercondylar box and its associated cam-and-post mechanism, and a more anatomic trochlea surface, so that the trochlea accommodates the natural patella.

Entities:  

Mesh:

Year:  2003        PMID: 12810970     DOI: 10.1177/230949900301100109

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  4 in total

1.  Total knee replacement arthroplasty with Buechel and Pappas knee: minimum 2-year follow-up.

Authors:  Kyoung Ho Moon; Seung Hyun Hong; Taek Ho Hong
Journal:  Clin Orthop Surg       Date:  2015-02-10

2.  Long-term follow-up of a non-randomised prospective cohort of one hundred and ninety two total knee arthroplasties using the NexGen implant.

Authors:  Alfredo Schiavone Panni; Franceso Falez; Rocco D'Apolito; Katia Corona; Carlo Perisano; Michele Vasso
Journal:  Int Orthop       Date:  2017-03-22       Impact factor: 3.075

3.  Aseptic tibial debonding as a cause of early failure in a modern total knee arthroplasty design.

Authors:  Diren Arsoy; Mark W Pagnano; David G Lewallen; Arlen D Hanssen; Rafael J Sierra
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

4.  Significant differences in rates of aseptic loosening between two variations of a popular total knee arthroplasty design.

Authors:  Michael Brown; Rohan Ramasubbu; Mark Jenkinson; James Doonan; Mark Blyth; Bryn Jones
Journal:  Int Orthop       Date:  2021-08-15       Impact factor: 3.075

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.