Literature DB >> 25729520

Total knee replacement arthroplasty with Buechel and Pappas knee: minimum 2-year follow-up.

Kyoung Ho Moon1, Seung Hyun Hong1, Taek Ho Hong1.   

Abstract

BACKGROUND: Clinical and radiologic evaluation and analyses of the surgeries using Buechel and Pappas (B-P) knee implants.
METHODS: The study was conducted on 60 patients who underwent 94 total knee replacement arthroplasty with B-P knee implants from May 2009 to December 2010. The results were compared to the results of 41 patients who underwent 60 knee joint surgeries using NexGen-LPS implants from January 2008 to August 2009.
RESULTS: The American Knee Society score of the B-P knee group increased from an average of 66.9 (clinical score) and 65.5 (functional score) to 93.4 and 90.3, respectively; while those for the NexGen-LPS group increased from an average of 68.8 (clinical score) and 62.4 (functional score) to 86.3 and 76, respectively. The average ranges of motion of the B-P knee group and the NexGen-LPS group were 119.1° and 114.8°, respectively, before surgery and improved to 121.0° and 123.0° at final follow-up after the surgery. The visual analogue scale scores for the B-P knee group and the NexGen-LPS group improved from 4.7 and 4.6 to 1.4 and 1.8, respectively. The flexion contracture also improved from 5.1° and 6.3° to 0.64° and 1.72°. The tibio-femoral angle for the B-P knee group and the NexGen-LPS group also improved greatly after the surgery, from varus 0.34° and 0.73° each to valgus 6.7° and 6.9°, respectively.
CONCLUSIONS: The evaluation of more than 2 years of total knee replacement arthroplasty using B-P knee implants showed good results. B-P knee implants showed a relatively higher degree of satisfaction in clinical knee score and less intraoperative bone mass removal than NexGen-LPS implants.

Entities:  

Keywords:  Buechel and Pappas knee; NexGen-LPS; Total knee arthroplasty

Mesh:

Year:  2015        PMID: 25729520      PMCID: PMC4329534          DOI: 10.4055/cios.2015.7.1.62

Source DB:  PubMed          Journal:  Clin Orthop Surg        ISSN: 2005-291X


  8 in total

1.  Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties.

Authors:  Scott Banks; Johan Bellemans; Hiroyuki Nozaki; Leo A Whiteside; Melinda Harman; W Andrew Hodge
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

Review 2.  Sports activity after total hip and knee arthroplasty : specific recommendations concerning tennis.

Authors:  Thorsten M Seyler; Michael A Mont; Phillip S Ragland; Munaf M Kachwala; Ronald E Delanois
Journal:  Sports Med       Date:  2006       Impact factor: 11.136

3.  Influence of positioning of prosthesis in total knee replacement.

Authors:  P A Lotke; M L Ecker
Journal:  J Bone Joint Surg Am       Date:  1977-01       Impact factor: 5.284

4.  Midvastus approach in total knee arthroplasty: a description and a cadaveric study determining the distance of the popliteal artery from the patellar margin of the incision.

Authors:  R E Cooper; G Trinidad; W R Buck
Journal:  J Arthroplasty       Date:  1999-06       Impact factor: 4.757

5.  The rotating platform mobile bearing TKA.

Authors:  R B Sorrells
Journal:  Orthopedics       Date:  1996-09       Impact factor: 1.390

6.  Early results of posterior-stabilised NexGen Legacy total knee arthroplasty.

Authors:  D Ip; W C Wu; W L Tsang
Journal:  J Orthop Surg (Hong Kong)       Date:  2003-06       Impact factor: 1.118

7.  A Comparison of Patella Retention versus Resurfacing for Moderate or Severe Patellar Articular Defects in Total Knee Arthroplasty: Minimum 5-year Follow-up Results.

Authors:  Seung Suk Seo; Chang Wan Kim; Sang Won Moon
Journal:  Knee Surg Relat Res       Date:  2011-09-26

8.  Comparison of mobile-bearing and fixed-bearing designs in high flexion total knee arthroplasty: using a navigation system.

Authors:  Tae Wan Kim; Shi Hwan Park; Jeung Tak Suh
Journal:  Knee Surg Relat Res       Date:  2012-02-28
  8 in total
  5 in total

1.  Intravenous iron supplementation with intra-articular administration of tranexamic acid reduces the rate of allogeneic transfusions after simultaneous bilateral total knee arthroplasty.

Authors:  Dong Won Suh; Seung-Beom Han; Jong-Hoon Park; Kuhoang Cheong; Bong Soo Kyung
Journal:  Blood Transfus       Date:  2016-07-22       Impact factor: 3.443

Review 2.  Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants.

Authors:  Charlotte Skjöldebrand; Joanne L Tipper; Peter Hatto; Michael Bryant; Richard M Hall; Cecilia Persson
Journal:  Mater Today Bio       Date:  2022-04-30

3.  Cadaveric study of the infrapatellar branch of the saphenous nerve: Can damage be prevented in total knee arthroplasty?

Authors:  Sung R Lee; Nicholas J P Dahlgren; Jackson R Staggers; Cesar de Cesar Netto; Amit Agarwal; Ashish Shah; Sameer Naranje
Journal:  J Clin Orthop Trauma       Date:  2018-03-09

4.  Evaluation of 1031 primary titanium nitride coated mobile bearing total knee arthroplasties in an orthopedic clinic.

Authors:  Stefan J M Breugem; Jeroen Linnartz; Inger Sierevelt; Jon D Bruijn; Marcel J M Driessen
Journal:  World J Orthop       Date:  2017-12-18

5.  Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study.

Authors:  Avatar Singh; Kanwar Kulwinder Singh
Journal:  J Clin Diagn Res       Date:  2017-09-01
  5 in total