Literature DB >> 12809662

Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate--a biomechanical study in a cadaveric model.

F Leung1, L Zhu, H Ho, W W Lu, S P Chow.   

Abstract

The stability of palmar plate fixation using a locking compression T-plate was compared with that of a conventional palmar T-plate and a dorsal T-plate in a cadaveric model of an AO type C2 fracture of distal radius. The wrist axial load transmission through the radius was tested for each fixation. The results show that, under 100N axial load, the palmar locking compression T-plate restores stability comparable to that of the intact radius, and is superior to conventional palmar or dorsal T-plates.

Entities:  

Mesh:

Year:  2003        PMID: 12809662     DOI: 10.1016/s0266-7681(03)00011-1

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  19 in total

1.  The cadaveric anatomy of the distal radius: implications for the use of volar plates.

Authors:  P A McCann; D Clarke; R Amirfeyz; R Bhatia
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

2.  Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly.

Authors:  N Schmelzer-Schmied; P Wieloch; A K Martini; W Daecke
Journal:  Int Orthop       Date:  2008-01-12       Impact factor: 3.075

3.  Complex fractures of the distal radius treated with angular stability plates.

Authors:  Marco Frattini; Giovanni Soncini; Maurizio Corradi; Bruno Panno; Silvio Tocco; Francesco Pogliacomi
Journal:  Chir Organi Mov       Date:  2009-07-21

4.  Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.

Authors:  Daniel Marsland; Chris M Hobbs; Philip S Sauvé
Journal:  Hand (N Y)       Date:  2014-12

5.  The treatment of distal radius articular fractures of C1-C2 type with DVR plate: analysis of 40 cases.

Authors:  L Tarallo; R Adani; R Mugnai; F Catani
Journal:  Musculoskelet Surg       Date:  2011-05-26

6.  Volar locking plate fixation for distal radius fractures: Does age affect outcome?

Authors:  Ahmed Ezzat; Santosh Baliga; Carol Carnegie; Alan Johnstone
Journal:  J Orthop       Date:  2016-02-22

7.  Radiological Outcomes of Distal Radius Fractures Managed with 2.7mm Volar Locking Plate Fixation-A Retrospective Analysis.

Authors:  Prem Kotian; Srikanth Mudiganty; Rajendra Annappa; Jose Austine
Journal:  J Clin Diagn Res       Date:  2017-01-01

8.  Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization.

Authors:  André Duprat; Juan José Hidalgo Diaz; Paul Vernet; Stéphanie Gouzou; Sybille Facca; Yuka Igeta; Philippe Liverneaux
Journal:  J Wrist Surg       Date:  2018-01-16

9.  Biomechanical comparison of different volar fracture fixation plates for distal radius fractures.

Authors:  Kareem Sobky; Todd Baldini; Kenneth Thomas; Joel Bach; Allison Williams; Jennifer Moriatis Wolf
Journal:  Hand (N Y)       Date:  2007-09-07

10.  A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.

Authors:  Ramin Mehin; Bryn Jones; Qingan Zhu; Henry Broekhuyse
Journal:  Can J Surg       Date:  2009-06       Impact factor: 2.089

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.