Effect of a denture cleanser on weight, surface roughness, and tensile bond strength of two resilient denture liners.

Renata M C Rodrigues Garcia1, Blanca T L Léon, Viviane B M Oliveira, Altair A Del Bel Cury.   

Abstract

STATEMENT OF PROBLEM: Denture cleansers used in clinical practice can damage resilient denture lining materials.
PURPOSE: This study evaluated the effects of a denture cleanser on weight change, roughness, and tensile bond strength on 2 denture resilient lining materials.
MATERIAL AND METHODS: Forty specimens of microwave acrylic resin (Onda-Cryl), 30 mm in diameter and 4 mm thick, were prepared to verify weight change and surface roughness. The specimens were divided into 4 groups consisting of 10 specimens each, relined with a resilient liner (Coe Soft or Dentusoft), and treated (Polident or tap water). To evaluate tensile bond strength, 12 specimens were used for each group. All specimens were stored in artificial saliva for 15 days, immersed once a day in Polident or tap water, and evaluated at 0 hours and after 24 hours and 7 and 15 days. Roughness was evaluated by use of a profilometer. Weight changes were recorded in milligrams and expressed as the percentage of weight difference between the periods of evaluation. Tensile bond strength was determined with a universal testing machine. The specimens were placed under tension until failure by a cross-speed of 5 mm/min with a 500 Kg load cell. The type of failure was determined by use of stereoscopic microscopy at original magnification x8. The data were submitted to analysis of variance and compared by Tukey's test (alpha=.05).
RESULTS: Specimens immersed in Polident showed higher and significant (P<.05) weight changes (%) than those immersed in water between 24 hours and 7 days (Coe Soft-Polident: 0.48 +/- 0.09; Coe Soft-water: 0.28 +/- 0.09; Dentusoft-Polident: 0.44 +/- 0.16; Dentusoft-water: 0.22 +/- 0.15) and between 7 and 15 days (Coe Soft-Polident: 0.08 +/- 0.04; Coe Soft-water: -0.17 +/- 0.05; Dentusoft-Polident: 0.01 +/- 0.04; Dentusoft-water: - 0.24 +/- 0.03). There was significant difference (P<.05) in roughness (in micrometers), between treatments after 7 days (Coe Soft-water: 4.07 +/- 0.22; Coe Soft-Polident: 3.36 +/- 0.52; Dentusoft-water: 3.68 +/- 0.72; Dentusoft-Polident: 3.26 +/- 0.41) and 15 days (Coe Soft-water: 4.88 +/- 0.29; Coe Soft-Polident:3.53 +/- 0.61; Dentusoft-water: 4.42 +/- 1.12; Dentusoft-Polident: 3.68 +/- 0.37). Tensile bond strength was highest (P<.05) after 15 days (Coe Soft-water: 5.19 +/- 0.93; Coe Soft-Polident: 4.40 +/- 0.38; Dentusoft-water: 4.42 +/- 1.15; Dentusoft-Polident: 4.84 +/- 1.14). Most failures were cohesive (Coe Soft: 76.04% and Dentusoft: 82.29%).
CONCLUSION: Within the limitations of this in vitro study, specimens immersed in Polident demonstrated increased weight changes of resilient liners when compared with tap water, but surface roughness and tensile bond strength were unaffected.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12806327     DOI: 10.1016/s0022-3913(03)00126-4

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  17 in total

1.  Effect of Aging on Bond Strength of Two Soft Lining Materials to a Denture Base Polymer.

Authors:  Alaa'a M Salloum
Journal:  J Indian Prosthodont Soc       Date:  2014-09-10

Review 2.  Resilient liners: a review.

Authors:  Shobha Rodrigues; Vidya Shenoy; Thilak Shetty
Journal:  J Indian Prosthodont Soc       Date:  2012-07-06

3.  Time Dependent Effect of a Denture Cleanser on the Sorption and Solubility of Four Soft Liners-An Invitro Study.

Authors:  Swathi Sudhapalli; Sruthikeerthi Sudhapalli
Journal:  J Clin Diagn Res       Date:  2016-04-01

4.  The influence of cyclic stress on surface properties of soft liners.

Authors:  M Murat Mutluay; Arzu Tezvergil-Mutluay
Journal:  Odontology       Date:  2016-07-25       Impact factor: 2.634

5.  Color stability of silicone or acrylic denture liners: an in vitro investigation.

Authors:  Gulfem Ergun; Isil Cekic Nagas
Journal:  Eur J Dent       Date:  2007-07

6.  Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin.

Authors:  Carlos Nelson Elias; Flavio Queiroz Henriques
Journal:  J Appl Oral Sci       Date:  2007-02       Impact factor: 2.698

7.  Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study.

Authors:  Rasleen Kaur Pahuja; Sandeep Garg; Sanjay Bansal; Rajat Harvinder Dang
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

8.  Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

Authors:  M Farzin; F Bahrani; E Adelpour
Journal:  J Dent (Shiraz)       Date:  2013-09

9.  Effect of beverages on the hardness and tensile bond strength of temporary acrylic soft liners to acrylic resin denture base.

Authors:  A Safari; M Vojdani; S Mogharrabi; N Iraji Nasrabadi; R Derafshi
Journal:  J Dent (Shiraz)       Date:  2013-12

Review 10.  Development of Candida-associated denture stomatitis: new insights.

Authors:  Tatiana Pereira-Cenci; Altair Antoninha Del Bel Cury; Wim Crielaard; Jacob Martien Ten Cate
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.