Literature DB >> 12798070

Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty.

J Mark Wilkinson1, Andrew J Hamer, Angela Rogers, Ian Stockley, Richard Eastell.   

Abstract

The aims of this study were to determine whether subjects with aseptic loosening after total hip arthroplasty (THA) have regional differences in periprosthetic bone mineral density (BMD) and systemic biochemical markers of bone turnover compared to subjects with successful implants.Proximal femoral and pelvic BMD were measured by dual energy X-ray absorptiometry and bone turnover markers were assayed in 49 subjects 12.6+/-4.3 (mean+/-SD) years after cemented THA. Femoral BMD was lower in Gruen zones 2, 5, 6, and 7 in subjects with a loose femoral implant (n=17) compared to those (n=32) with fixed femoral implants (P<0.05 all comparisons). This BMD difference was greatest (-31%, P=0.02) in the proximal and medial region of the femur. Subjects with femoral loosening had higher levels of the bone resorption marker N-telopeptides of type-I collagen (P=0.02) than those with a fixed femoral implant. No differences in pelvic BMD or bone turnover markers were found between subjects with loose (n=18) versus fixed (n=31) pelvic implants. This study suggests that failure of femoral components after cemented THA is associated with region-specific decreases in BMD and an increase in urinary excretion of N-telopeptide cross-links of type-I collagen. These surrogate outcome markers may be of value in monitoring response to antiresorptive therapies used to treat periprosthetic osteolysis, although the diagnosis of aseptic loosening remains clinical and radiological.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12798070     DOI: 10.1016/S0736-0266(02)00237-1

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  25 in total

1.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

Review 2.  [Wear particles: key to aseptic prosthetic loosening?].

Authors:  M Otto; J Kriegsmann; T Gehrke; S Bertz
Journal:  Pathologe       Date:  2006-11       Impact factor: 1.011

3.  Development of periprosthetic bone mass density around the cementless Metha® short hip stem during three year follow up-a prospective radiological and clinical study.

Authors:  Laura Augustin; Sarah Boller; Cathrein Bobach; Alexander Jahnke; Gafar Adam Ahmed; Markus Rickert; Bernd Alexander Ishaque
Journal:  Int Orthop       Date:  2018-09-03       Impact factor: 3.075

4.  Sophocarpine attenuates wear particle-induced implant loosening by inhibiting osteoclastogenesis and bone resorption via suppression of the NF-κB signalling pathway in a rat model.

Authors:  Chen-He Zhou; Zhong-Li Shi; Jia-Hong Meng; Bin Hu; Chen-Chen Zhao; Yu-Te Yang; Wei Yu; Ze-Xin Chen; Boon Chin Heng; Virginia-Jeni Akila Parkman; Shuai Jiang; Han-Xiao Zhu; Hao-Bo Wu; Wei-Liang Shen; Shi-Gui Yan
Journal:  Br J Pharmacol       Date:  2018-02-14       Impact factor: 8.739

5.  Clinical Factors, Disease Parameters, and Molecular Therapies Affecting Osseointegration of Orthopedic Implants.

Authors:  Hilal Maradit Kremers; Eric A Lewallen; Andre J van Wijnen; David G Lewallen
Journal:  Curr Mol Biol Rep       Date:  2016-06-29

6.  Bone remodelling around HA-coated acetabular cups : a DEXA study with a 3-year follow-up in a randomised trial.

Authors:  M B Laursen; P T Nielsen; K Søballe
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

7.  Bone remodeling around stable uncemented titanium stems during the second decade after total hip arthroplasty: a DXA study at 12 and 17 years.

Authors:  C Merle; M R Streit; C Volz; M Pritsch; T Gotterbarm; P R Aldinger
Journal:  Osteoporos Int       Date:  2010-11-23       Impact factor: 4.507

8.  Is tartrate-resistant acid phosphatase 5b a potent bio-marker for late stage aseptic implant loosening?

Authors:  Gerrit Steffen Maier; Christian Eberhardt; Marco Strauch; Konstantinos Kafchitsas; Andreas A Kurth
Journal:  Int Orthop       Date:  2014-08-01       Impact factor: 3.075

9.  Genetic susceptibility to total hip arthroplasty failure: a preliminary study on the influence of matrix metalloproteinase 1, interleukin 6 polymorphisms and vitamin D receptor.

Authors:  M H A Malik; F Jury; A Bayat; W E R Ollier; P R Kay
Journal:  Ann Rheum Dis       Date:  2007-03-15       Impact factor: 19.103

10.  Primary stability of the Fitmore stem: biomechanical comparison.

Authors:  Wojciech Pepke; Jan Nadorf; Volker Ewerbeck; Marcus R Streit; Stefan Kinkel; Tobias Gotterbarm; Michael W Maier; J Philippe Kretzer
Journal:  Int Orthop       Date:  2013-10-22       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.