Literature DB >> 12779151

Phase retrieval for high-numerical-aperture optical systems.

Bridget M Hanser1, Mats G L Gustafsson, David A Agard, John W Sedat.   

Abstract

We describe a phase retrieval approach for intensity point-spread functions of high-numerical-aperture optical systems such as light microscopes. The method calculates a generalized pupil function defined on a spherical shell, using measured images at several defocus levels. The resultant pupil functionsreproduce measured point-source images significantly better than does an ideal imaging model. Availability of pupil function information will facilitate new approaches to aberration correction in such systems.

Mesh:

Year:  2003        PMID: 12779151     DOI: 10.1364/ol.28.000801

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  18 in total

1.  Closed loop adaptive optics for microscopy without a wavefront sensor.

Authors:  Peter Kner; Lukman Winoto; David A Agard; John W Sedat
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-24

2.  Characterization of spatially varying aberrations for wide field-of-view microscopy.

Authors:  Guoan Zheng; Xiaoze Ou; Roarke Horstmeyer; Changhuei Yang
Journal:  Opt Express       Date:  2013-07-01       Impact factor: 3.894

Review 3.  Super-Resolution Microscopy: Shedding Light on the Cellular Plasma Membrane.

Authors:  Matthew B Stone; Sarah A Shelby; Sarah L Veatch
Journal:  Chem Rev       Date:  2017-02-17       Impact factor: 60.622

4.  High numerical aperture Fourier ptychography: principle, implementation and characterization.

Authors:  Xiaoze Ou; Roarke Horstmeyer; Guoan Zheng; Changhuei Yang
Journal:  Opt Express       Date:  2015-02-09       Impact factor: 3.894

5.  Automated sensorless single-shot closed-loop adaptive optics microscopy with feedback from computational adaptive optics.

Authors:  Rishyashring R Iyer; Yuan-Zhi Liu; Stephen A Boppart
Journal:  Opt Express       Date:  2019-04-29       Impact factor: 3.894

6.  High-NA open-top selective-plane illumination microscopy for biological imaging.

Authors:  Ryan Mcgorty; Dan Xie; Bo Huang
Journal:  Opt Express       Date:  2017-07-24       Impact factor: 3.894

7.  Aberration correction method based on double-helix point spread function.

Authors:  Zhaojun Wang; Yanan Cai; Yansheng Liang; Dan Dan; Baoli Yao; Ming Lei
Journal:  J Biomed Opt       Date:  2018-09       Impact factor: 3.170

8.  Three dimensional single molecule localization using a phase retrieved pupil function.

Authors:  Sheng Liu; Emil B Kromann; Wesley D Krueger; Joerg Bewersdorf; Keith A Lidke
Journal:  Opt Express       Date:  2013-12-02       Impact factor: 3.894

9.  Wide field-of-view fluorescence image deconvolution with aberration-estimation from Fourier ptychography.

Authors:  Jaebum Chung; Jinho Kim; Xiaoze Ou; Roarke Horstmeyer; Changhuei Yang
Journal:  Biomed Opt Express       Date:  2016-01-07       Impact factor: 3.732

10.  Three-Dimensional Single-Molecule Localization Microscopy in Whole-Cell and Tissue Specimens.

Authors:  Sheng Liu; Hyun Huh; Sang-Hyuk Lee; Fang Huang
Journal:  Annu Rev Biomed Eng       Date:  2020-04-03       Impact factor: 9.590

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.