Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors.

Jen-San Tsai1, Mark J Rivard, Mark J Engler, John E Mignano, David E Wazer, William A Shucart.   

Abstract

Though the 4 mm Gamma Knife helmet is used routinely, there is disagreement in the Gamma Knife users community on the value of the 4 mm helmet relative output factor. A range of relative output factors is used, and this variation may impair observations of dose response and optimization of prescribed dose. To study this variation, measurements were performed using the following radiation detectors: silicon diode, diamond detector, radiographic film, radiochromic film, and TLD cubes. To facilitate positioning of the silicon diode and diamond detector, a three-dimensional translation micrometer was used to iteratively determine the position of maximum detector response. Positioning of the films and TLDs was accomplished by manufacturing custom holders for each technique. Results from all five measurement techniques indicate that the 4 mm helmet relative output factor is 0.868 +/- 0.014. Within the experimental uncertainties, this value is in good agreement with results obtained by other investigators using diverse techniques.

Entities:  

Mesh:

Year:  2003        PMID: 12773008     DOI: 10.1118/1.1567736

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Development of a stereotactic device for gamma knife irradiation of small animals.

Authors:  Hyun-Tai Chung; Young Seob Chung; Dong Gyu Kim; Sun Ha Paek; Keun-Tae Cho
Journal:  J Korean Neurosurg Soc       Date:  2008-01-20

2.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  Replacing gamma knife beam-profiles on film with point-detector scans.

Authors:  Benedikt Rudek; Kenneth Bernstein; Sunshine Osterman; Tanxia Qu
Journal:  J Appl Clin Med Phys       Date:  2022-01-09       Impact factor: 2.102

4.  Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

Authors:  Jinkoo Kim; Ning Wen; Jian-Yue Jin; Nicole Walls; Sangroh Kim; Haisen Li; Lei Ren; Yimei Huang; Anthony Doemer; Kathleen Faber; Tina Kunkel; Ahssan Balawi; Kimberly Garbarino; Kenneth Levin; Samir Patel; Munther Ajlouni; Brett Miller; Teamor Nurushev; Calvin Huntzinger; Raymond Schulz; Indrin J Chetty; Benjamin Movsas; Samuel Ryu
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

5.  Determination of Collimator Helmet Factors for Leksell Gamma Knife 4C Unit Using GAF Chromic EBT3 Film and ImageJ Software.

Authors:  Ponnusamy Natesan; Senthil Manikandan Palaniappan; Muthuvinayagam M; K M Ganesh; Malla Bhaskara Rao
Journal:  Asian Pac J Cancer Prev       Date:  2021-12-01

6.  Technical note: the effect of the 4-mm-collimator output factor on gamma knife dose distributions.

Authors:  John P Gibbons; Dimitris Mihailidis; Curtis Worthington; Hassaan Alkhatib; Raleigh Boulware; Robert Clark; Burke Dial; William Neglia
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

7.  Validation of MLC-based linac radiosurgery for trigeminal neuralgia.

Authors:  M Tynan R Stevens; Eric C Lobb; Kamil M Yenice
Journal:  J Appl Clin Med Phys       Date:  2018-06-14       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.