Literature DB >> 12773000

Characteristics of sensitometric curves of radiographic films.

X R Zhu1, S Yoo, P A Jursinic, D F Grimm, F Lopez, J J Rownd, M T Gillin.   

Abstract

A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the relationship between optical density and dose, commonly known as the sensitometric curve, depends linearly on the dose at low densities. Unlike XV film, the sensitometric curve of EDR film irradiated by megavoltage x rays is not linearly dependent on the dose at low densities. In this work, to understand the mechanisms governing the shape of the sensitometric curves, EDR film was studied with kilovoltage x rays, 60Co gamma rays, megavoltage x rays, and electron beams. As a comparison, XV film was also studied with the same beams mentioned above. The model originally developed by Silberstein [J. Opt. Soc. Am. 35, 93-107, 1945)] is used to fit experimental data. It is found that the single hit model can be used to predict the sensitometric curve for XV films irradiated by all beams used in this work and for EDR films exposed to kilovoltage x rays. For EDR film irradiated by 60Co gamma rays, megavoltage x rays, and electron beams, the double hit model is used to fit the sensitometric curves. For doses less than 100 cGy, a systematic difference between measured densities and that predicted by the double hit model is observed. Possible causes of the observed differences are discussed. The results of this work provide a theoretical explanation of the sensitometric behavior of EDR film.

Entities:  

Mesh:

Year:  2003        PMID: 12773000     DOI: 10.1118/1.1568979

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Energy dependence of radiochromic dosimetry films for use in radiotherapy verification.

Authors:  Krzysztof Chełmiński; Wojciech Bulski; Dietmar Georg; Dominika Bodzak; Zbigniew Maniakowski; Dominika Oborska; Joanna Rostkowska; Małgorzata Kania
Journal:  Rep Pract Oncol Radiother       Date:  2010-03-30

2.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  Development of multi-planar dose verification by use of a flat panel EPID for intensity-modulated radiation therapy.

Authors:  Yuji Nakaguchi; Fujio Araki; Tomohiro Kouno; Takeshi Ono; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2012-12-11

4.  Decreased GABA(B) receptors in the cingulate cortex and fusiform gyrus in autism.

Authors:  Adrian L Oblak; Terrell T Gibbs; Gene J Blatt
Journal:  J Neurochem       Date:  2010-06-12       Impact factor: 5.372

5.  Experimental dosimetry of EDR2 films in scanning carbon-ion irradiation.

Authors:  Weiwei Wang; Yu Deng; Zhijie Huang
Journal:  J Appl Clin Med Phys       Date:  2022-05-20       Impact factor: 2.243

6.  Dosimetric evaluation of a novel high dose rate (HDR) intraluminal / interstitial brachytherapy applicator for gastrointestinal and bladder cancers.

Authors:  Sanaz Hariri Tabrizi; Seyyed Mahmoud Reza Aghamiri; Siamak Najarian; Ramin Jaberi
Journal:  J Appl Clin Med Phys       Date:  2010-12-02       Impact factor: 2.102

7.  Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters.

Authors:  Shu-Hui Hsu; Ravi Kulasekere; Peter L Roberson
Journal:  J Appl Clin Med Phys       Date:  2010-08-05       Impact factor: 2.102

8.  Use of a matchline dosimetry analysis tool (MDAT) to quantify dose homogeneity in the region between abutting tangential and supraclavicular radiation fields.

Authors:  Kenneth L Homann; B Earl Gates; Mohammad Salehpour; David S Followill; Steven M Kirsner; R Allen White; Thomas A Buchholz; Karl L Prado
Journal:  J Appl Clin Med Phys       Date:  2010-07-27       Impact factor: 2.102

9.  Radiographic film dosimetry for IMRT fields in the nearsurface buildup region.

Authors:  Peter L Roberson; Jean M Moran; Ravi Kulasekere
Journal:  J Appl Clin Med Phys       Date:  2008-10-24       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.