Plastic scintillation dosimetry: optimization of light collection efficiency.

A Sam Beddar1, Susan Law, Natalka Suchowerska, T Rockwell Mackie.   

Abstract

Practical contemporary radiotherapy dosimetry systems used for dose measurement and verification are ionization chambers (which typically have at least a 0.1 cm3 air cavity volume), thermoluminescent dosimeters (TLDs) and silicon diodes. However, during the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, due to their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The objectives of this study are to identify the factors preventing this new technology from realizing its full potential in commercial applications. A definition of signal to noise ratio (S/N) will be proposed for this category of detectors. In doing so the S/N ratio for an early prototype design has been calculated and/or measured. Criteria to optimize the response and sensitivity of this category of detectors are presented.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12765328     DOI: 10.1088/0031-9155/48/9/305

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.

Authors:  Lilie L W Wang; David Klein; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

Authors:  Mathieu Guillot; Luc Gingras; Louis Archambault; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization.

Authors:  Frédéric Lacroix; A Sam Beddar; Mathieu Guillot; Luc Beaulieu; Luc Gingras
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

4.  Toward a real-time in vivo dosimetry system using plastic scintillation detectors.

Authors:  Louis Archambault; Tina M Briere; Falk Pönisch; Luc Beaulieu; Deborah A Kuban; Andrew Lee; Sam Beddar
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-16       Impact factor: 7.038

5.  A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.

Authors:  Francois Therriault-Proulx; Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.