| Literature DB >> 35735641 |
Fotis Dimopoulos1, Konstantinos Kodonas1, Christos Gogos1.
Abstract
The purpose of this study was to examine the bond strength of AH26 to human coronal dentin exposed to DMSO. A total of 70 dentin specimens were equally divided into two groups. Each dentin surface was pre-treated with 2 mL of 2.5% NaOCl, 3 mL of EDTA 17%, and distilled water. One group was finally rinsed with 50% DMSO. Following the AH26 application, the bond strength was tested by subjecting the samples to a shear load at a crosshead speed of 0.5 mm/min using universal testing equipment. The results according to paired samples t-test indicated that there was a statistically insignificant difference between the two groups. Therefore, DMSO had no effect on the bond strength of AH26 root sealer to dentin.Entities:
Keywords: AH26; bond strength; dentistry; dimethyl sulfoxide; sealer
Year: 2022 PMID: 35735641 PMCID: PMC9221750 DOI: 10.3390/dj10060100
Source DB: PubMed Journal: Dent J (Basel) ISSN: 2304-6767
Materials used in this study.
| Materials | Manufacturer | Composition |
|---|---|---|
| AH26 silver free | Dentsply, Konstanz, Switzerland | Powder: bismuth oxide, methenamine |
| DMSO | Santa Cruz Biotechnology, Heidelberg, Germany | C2H2OS |
Scheme 1Specimen preparation ((a) section below the cementoenamel junction (b) longitudinally section in the buccolingual direction from both the mesial and distal surface (c) remaining specimen (d) section in the middle of the remaining specimen resulting to two equal parts).
Figure 1Modified stationary clamp for plastic cylinder stabilization.
Figure 2Modified stationary clamp for plastic cylinder stabilization.
Dentin treatment and materials.
| Group | Dentin Treatment | Materials |
|---|---|---|
| A | 3 mL EDTA 17%, 2 min | AH26 |
| B | 3 mL EDTA 17%, 2 min | DMSO |
Descriptive statistics of the involved variables.
| Variable | Mean | Std Deviation | Minimum | Maximum |
|---|---|---|---|---|
| Group A | 0.8924 | 0.3753 | 0.2256 | 1.7162 |
| Group B | 0.8927 | 0.4164 | 0.2157 | 2.0299 |
Paired samples t-test results.
| Pair of Variables | Mean Difference | Standard Error | t-Statistic | |
|---|---|---|---|---|
| Group A–Group B | −0.00028 | 0.07119 | −0.004 | 0.997 |
Fracture models of the materials.
| Material | Adhesive Failure | Cohesive Failure | Mixed Mode Failure | Confidence Interval |
|---|---|---|---|---|
| AH26 | 27 (77.1%) | 5 (14.3%) | 3 (8.6%) | 95% |
| AH26 + DMSO | 25 (71.5%) | 6 (17.1%) | 4 (11.4%) | 95% |
Figure 3Adhesive failure—group A.
Figure 4Adhesive failure—group B.
Figure 5Cohesive failure—group A.
Figure 6Cohesive failure—group B.
Figure 7Mixed failure—group A.
Figure 8Mixed failure—group B.