Literature DB >> 12742451

In vitro performance of intramedullary cement restrictors in total hip arthroplasty.

C Heisel1, T Norman, R Rupp, M Pritsch, V Ewerbeck, S J Breusch.   

Abstract

Contemporary cementing techniques in total hip arthroplasty include the use of a cement restrictor to occlude the intramedullary canal. As there are many different designs currently available it was the aim of our study to compare the stability of eight different systems. We investigated the displacement and the ability to occlude the femur of these cement restrictors during standardised cementing of artificial and fresh frozen femora. The maximal intramedullary pressures and the displacement of the plugs were continuously recorded and statistically evaluated. The results revealed significant differences between the tested cement restrictors. The expandable REX Cement Stop and the Exeter Plug achieved the highest stability and the least cement leakage. The more rigid designs (Palacos Plug, BUCK, Universal) in contrast showed inferior performance. Our biomechanical study emphasises the importance of cement restrictor selection, which can have a crucial influence on the fixation of a cemented total hip replacement.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12742451     DOI: 10.1016/s0021-9290(03)00017-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

Review 1.  Bone cement.

Authors:  Raju Vaishya; Mayank Chauhan; Abhishek Vaish
Journal:  J Clin Orthop Trauma       Date:  2013-12-15

Review 2.  [Cementing techniques for hip resurfacing arthroplasty. What do we know?].

Authors:  R G Bitsch; T P Schmalzried
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

3.  Bone cement (PMMA) arterio-venogram following total hip arthroplasty - Case series.

Authors:  Hemanth Kumar Venkatesh; Mohammad Shoaib
Journal:  J Clin Orthop Trauma       Date:  2017-08-30

4.  Pulmonary cement embolism in a child following total elbow replacement for primitive neuroectodermal tumour (PNET) of the humerus.

Authors:  Subramaniam Ramanathan; Tushar Vora; Ashish Gulia; Abhishek Mahajan; Subhash Desai
Journal:  Skeletal Radiol       Date:  2017-02-23       Impact factor: 2.199

Review 5.  Osteolysis in cemented total hip arthroplasty involving the OptiPlug cement restrictor: more than an incident?

Authors:  N M A I Hanssen; M G M Schotanus; A D Verburg
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-28

6.  The Relative Merits of Cemented and Uncemented Prostheses in Total Hip Arthroplasty.

Authors:  Joanna Maggs; Matthew Wilson
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

7.  Charnley femoral cemented stem with a permeable and resorbable cement restrictor and low-viscosity cement - Clinical and radiographical evaluation of 100 cases at a mean follow-up of 6.55 years.

Authors:  Jean-Louis Prudhon; Jacques H Caton; Thierry Aslanian
Journal:  SICOT J       Date:  2019-11-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.