Abstract

OBJECTIVES: The latest development in echocardiography is the hand-held ultrasound device. Previous studies have shown that portable ultrasound devices detect major cardiovascular pathology better than the physical examination, but their diagnostic accuracy is still not known. The purpose of this study was to compare the results of examinations made with portable devices to those obtained with higher-scale platforms. PATIENTS AND
METHOD: 211 consecutive unselected patients were included in the study. Patients were randomly studied with a portable device and a standard platform (considered the gold standard for comparison) by cardiologists experienced in echocardiography. Parameters of cardiac morphology and function, and valvular regurgitation were compared and analyzed using the McNemar paired test. Differences of more than one grade were considered major differences.
RESULTS: The subjective assessment of the studies made with the portable device was significantly worse. The correlation between estimates of left ventricular function (differences not statistically significant) was adequate, but significant differences were detected in the evaluation of left atrial enlargement, left ventricular hypertrophy, aortic root enlargement, and mitral and tricuspid regurgitation.
CONCLUSIONS: Hand-held cardiac ultrasound devices do not satisfy criteria for a complete echocardiographic study. They provide accurate information about ventricular function but fail to adequately measure cardiac chambers or assess valve function.

Entities:  

Mesh:

Year:  2003        PMID: 12737786     DOI: 10.1016/s0300-8932(03)76903-6

Source DB:  PubMed          Journal:  Rev Esp Cardiol        ISSN: 0300-8932            Impact factor:   4.753


  2 in total

1.  Portable spectral Doppler echocardiographic device: overcoming limitations.

Authors:  J Quiles; M A García-Fernández; P B Almeida; E Pérez-David; J Bermejo; M Moreno; P Avanzas
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

2.  Screening for rheumatic heart disease: quality and agreement of focused cardiac ultrasound by briefly trained health workers.

Authors:  Daniel Engelman; Joseph H Kado; Bo Reményi; Samantha M Colquhoun; Jonathan R Carapetis; Nigel J Wilson; Susan Donath; Andrew C Steer
Journal:  BMC Cardiovasc Disord       Date:  2016-02-01       Impact factor: 2.298

  2 in total