Literature DB >> 1272089

Transthoracic impedance to direct current discharge: effect of repeated countershocks.

C F Dahl, G A Ewy, M D Ewy, E D Thomas.   

Abstract

The effect of repeated countershocks on transthoracic apparent impedance to direct current (dc) defibrillator discharges was studied. Repeated dc countershocks result in a progressive decrease in transthoracic apparent impedance that is dependent upon the time interval between countershocks. This decrease was significantly greater in the group of animals shocked at 3-min intervals compared to the groups shocked at 15-sec intervals (P less than 0.001) or at 1-min intervals (P less than 0.005). Since lowered impedance results in higher delivered current for the same energy setting on a defibrillator, this observation may help to explain the enhanced effectiveness of repeated countershocks in defibrillation. Plots of simultaneous current against voltage during transthoracic dc discharge revealed that the current lagged slightly behind voltage during the rising phase of the recording, but that current and voltage were nearly simultaneous during the falling phase. This effect appears to be similar to an ionization phenomenon in that the effective impedance asymptotically approaches a lower value with increasingly applied voltage. This might explain why transthoracic impedance is highest at low energy countershocks and decreases with higher energy countershock.

Entities:  

Mesh:

Year:  1976        PMID: 1272089

Source DB:  PubMed          Journal:  Med Instrum        ISSN: 0090-6689


  7 in total

1.  External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements.

Authors:  G L Botto; A Politi; W Bonini; T Broffoni; R Bonatti
Journal:  Heart       Date:  1999-12       Impact factor: 5.994

2.  eHEART: www.heartjnl.com.

Authors: 
Journal:  Heart       Date:  1999-12       Impact factor: 5.994

3.  Determinants of successful transthoracic defibrillation and outcome in ventricular fibrillation.

Authors:  G W Dalzell; A A Adgey
Journal:  Br Heart J       Date:  1991-06

4.  Thoracic impedance of adult males during defibrillation--a curious discrepancy.

Authors:  J W Machin; J Brownhill; A Furness
Journal:  Med Biol Eng Comput       Date:  1987-11       Impact factor: 2.602

5.  Randomised comparison of electrode positions for cardioversion of atrial fibrillation.

Authors:  T P Mathew; A Moore; M McIntyre; M T Harbinson; N P Campbell; A A Adgey; G W Dalzell
Journal:  Heart       Date:  1999-06       Impact factor: 5.994

Review 6.  Electric cardioversion of atrial fibrillation.

Authors:  Maen Nusair; Greg C Flaker; Anand Chockalingam
Journal:  Mo Med       Date:  2010 Jan-Feb

7.  Analysis of transthoracic impedance during real cardiac arrest defibrillation attempts in older children and adolescents: are stacked-shocks appropriate?

Authors:  Dana E Niles; Akira Nishisaki; Robert M Sutton; Sara Brunner; Mette Stavland; Shruthi Mahadevaiah; Peter A Meaney; Matthew R Maltese; Robert A Berg; Vinay M Nadkarni
Journal:  Resuscitation       Date:  2010-08-13       Impact factor: 5.262