BACKGROUND AND
PURPOSE: In the application of functional MR imaging for presurgical planning, high reproducibility is required. We investigated whether the reproducibility of functional MR imaging results in healthy volunteers depended on the MR system used.
METHODS: Visual functional MR imaging reproducibility experiments were performed with 12 subjects, by using two comparable 1.5-T MR systems from different manufacturers. Each session consisted of two runs, and each subject underwent three sessions, two on one system and one on the other. Reproducibility measures D (distance in millimeters) and R(size) and R(overlap) (ratios) were calculated under three conditions: same session, which compared runs from one session; intersession, which compared runs from different sessions but from the same system; and intermachine, which compared runs from the two different systems. The data were averaged per condition and per system, and were compared.
RESULTS: The average same-session values of the reproducibility measures did not differ significantly between the two systems. The average intersession values did not differ significantly as to the volume of activation (R(size)), but did differ significantly as to the location of this volume (D and R(overlap)). The average intermachine reproducibility did not differ significantly from the average intersession reproducibility of the MR system with the worst reproducibility.
CONCLUSION: The location of activated voxels from visual functional MR imaging experiments varied more between sessions on one MR system than on other MR system. The amount of the activated voxels is independent of the MR system used. We suggest that sites performing functional MR imaging for presurgical planning measure the intersession reproducibility to determine an accurate surgical safety margin.

Mesh:

Year:  2003        PMID: 12695198      PMCID: PMC8148661     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  24 in total

1.  Stability, repeatability, and the expression of signal magnitude in functional magnetic resonance imaging.

Authors:  M S Cohen; R M DuBois
Journal:  J Magn Reson Imaging       Date:  1999-07       Impact factor: 4.813

2.  FMRI of visual encoding: reproducibility of activation.

Authors:  W C Machielsen; S A Rombouts; F Barkhof; P Scheltens; M P Witter
Journal:  Hum Brain Mapp       Date:  2000-03       Impact factor: 5.038

3.  Variability in fMRI: an examination of intersession differences.

Authors:  D J McGonigle; A M Howseman; B S Athwal; K J Friston; R S Frackowiak; A P Holmes
Journal:  Neuroimage       Date:  2000-06       Impact factor: 6.556

4.  Concordance between functional magnetic resonance imaging and intraoperative language mapping.

Authors:  M I Ruge; J Victor; S Hosain; D D Correa; N R Relkin; V Tabar; C Brennan; P H Gutin; J Hirsch
Journal:  Stereotact Funct Neurosurg       Date:  1999       Impact factor: 1.875

5.  Metabolic and electrophysiological validation of functional MRI.

Authors:  T Krings; M Schreckenberger; V Rohde; H Foltys; U Spetzger; O Sabri; M H Reinges; S Kemeny; P T Meyer; W Möller-Hartmann; M Korinth; J M Gilsbach; U Buell; A Thron
Journal:  J Neurol Neurosurg Psychiatry       Date:  2001-12       Impact factor: 10.154

6.  Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.

Authors:  V J Schmithorst; B J Dardzinski; S K Holland
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

7.  Reproducibility of visual activation in functional magnetic resonance imaging at very high field strength (4 Tesla).

Authors:  A Miki; J Raz; S A Englander; N S Butler; T G van Erp; J C Haselgrove; G T Liu
Journal:  Jpn J Ophthalmol       Date:  2001 Jan-Feb       Impact factor: 2.447

8.  Improved assessment of significant activation in functional magnetic resonance imaging (fMRI): use of a cluster-size threshold.

Authors:  S D Forman; J D Cohen; M Fitzgerald; W F Eddy; M A Mintun; D C Noll
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

9.  Methods for assessing accuracy and reliability in functional MRI.

Authors:  T H Le; X Hu
Journal:  NMR Biomed       Date:  1997 Jun-Aug       Impact factor: 4.044

10.  Improved image registration by using Fourier interpolation.

Authors:  W F Eddy; M Fitzgerald; D C Noll
Journal:  Magn Reson Med       Date:  1996-12       Impact factor: 4.668

View more
  12 in total

Review 1.  Function biomedical informatics research network recommendations for prospective multicenter functional MRI studies.

Authors:  Gary H Glover; Bryon A Mueller; Jessica A Turner; Theo G M van Erp; Thomas T Liu; Douglas N Greve; James T Voyvodic; Jerod Rasmussen; Gregory G Brown; David B Keator; Vince D Calhoun; Hyo Jong Lee; Judith M Ford; Daniel H Mathalon; Michele Diaz; Daniel S O'Leary; Syam Gadde; Adrian Preda; Kelvin O Lim; Cynthia G Wible; Hal S Stern; Aysenil Belger; Gregory McCarthy; Burak Ozyurt; Steven G Potkin
Journal:  J Magn Reson Imaging       Date:  2012-02-07       Impact factor: 4.813

2.  Assessment of multiple task activation and reproducibility in patients with benign and low-grade neoplasm.

Authors:  R D McKinsey; C H Moritz; M E Meyerand; W A Tomé
Journal:  Technol Cancer Res Treat       Date:  2010-08

3.  Reproducibility of fMRI activations associated with auditory sentence comprehension.

Authors:  Javier Gonzalez-Castillo; Thomas M Talavage
Journal:  Neuroimage       Date:  2010-10-07       Impact factor: 6.556

4.  Multisite reliability of cognitive BOLD data.

Authors:  Gregory G Brown; Daniel H Mathalon; Hal Stern; Judith Ford; Bryon Mueller; Douglas N Greve; Gregory McCarthy; James Voyvodic; Gary Glover; Michele Diaz; Elizabeth Yetter; I Burak Ozyurt; Kasper W Jorgensen; Cynthia G Wible; Jessica A Turner; Wesley K Thompson; Steven G Potkin
Journal:  Neuroimage       Date:  2010-10-13       Impact factor: 6.556

5.  The Neuro/PsyGRID calibration experiment: identifying sources of variance and bias in multicenter MRI studies.

Authors:  John Suckling; Anna Barnes; Dominic Job; David Brennan; Katherine Lymer; Paola Dazzan; Tiago Reis Marques; Clare MacKay; Shane McKie; Steve R Williams; Steven C R Williams; Bill Deakin; Stephen Lawrie
Journal:  Hum Brain Mapp       Date:  2011-03-21       Impact factor: 5.038

Review 6.  Functional magnetic resonance imaging for neurosurgical planning in neurooncology.

Authors:  Erik-Jan Vlieger; Charles B Majoie; Sieger Leenstra; Gerard J Den Heeten
Journal:  Eur Radiol       Date:  2004-05-18       Impact factor: 5.315

7.  Reduced Frontoparietal Activity in Schizophrenia Is Linked to a Specific Deficit in Goal Maintenance: A Multisite Functional Imaging Study.

Authors:  Andrew B Poppe; Deanna M Barch; Cameron S Carter; James M Gold; John Daniel Ragland; Steven M Silverstein; Angus W MacDonald
Journal:  Schizophr Bull       Date:  2016-04-08       Impact factor: 9.306

Review 8.  New approaches for precise response evaluation in hepatocellular carcinoma.

Authors:  Koichi Hayano; Jorge M Fuentes-Orrego; Dushyant V Sahani
Journal:  World J Gastroenterol       Date:  2014-03-28       Impact factor: 5.742

9.  Imaging for assessment of treatment response in hepatocellular carcinoma: Current update.

Authors:  Koichi Hayano; Sang Ho Lee; Dushyant V Sahani
Journal:  Indian J Radiol Imaging       Date:  2015 Apr-Jun

10.  Characterization of Nyquist ghost in EPI-fMRI acquisition sequences implemented on two clinical 1.5 T MR scanner systems: effect of readout bandwidth and echo spacing.

Authors:  Marco Giannelli; Stefano Diciotti; Carlo Tessa; Mario Mascalchi
Journal:  J Appl Clin Med Phys       Date:  2010-07-12       Impact factor: 2.102