Literature DB >> 12689893

Effect of individualized compensation for anterior segment birefringence on retinal nerve fiber layer assessments as determined by scanning laser polarimetry.

Neil T Choplin1, Qienyuan Zhou, Robert W Knighton.   

Abstract

PURPOSE: Scanning laser polarimetry estimates retinal nerve fiber layer (RNFL) thickness through measurement of retardation of a polarized laser light passing through the naturally birefringent RNFL and cornea. The commercial instrument, the GDx Nerve Fiber Analyzer (Laser Diagnostic Technologies, Inc., San Diego, CA), uses an anterior segment compensator of fixed magnitude and slow polarization axis to eliminate the contribution of the cornea to the total signal. Previous studies have shown up to 30% of patients are not adequately compensated by this method. The aim of this study was to determine the effect of individualized anterior segment compensation using a newly designed variable compensator on estimates of retinal nerve fiber layer thickness compared with those as determined with the fixed compensator in the commercial device.
DESIGN: Comparative, observational case series. PARTICIPANTS: Twenty-eight eyes from 14 normal participants and 24 eyes from 12 patients with bilateral glaucoma.
METHODS: Using information derived from a scan of the macula, a newly designed variable anterior segment compensator for the GDx was set to neutralize anterior segment birefringence. Normal participants and patients with glaucoma underwent RNFL measurements using the standard (fixed) compensator and the variable compensator. The results were compared using Hotelling's generalized means test and Bonferroni's adjustment for multiple comparisons. MAIN OUTCOME MEASURES: Standard GDx modulation and thickness parameters as determined with the fixed and variable compensators.
RESULTS: All thickness values were statistically significantly lower as determined with the variable compensator, with no discernible differences in any of the modulation parameters.
CONCLUSIONS: Individualized anterior segment compensation lowers the RNFL thickness values as determined by scanning laser polarimetry compared with those determined with the standard fixed compensator. This may narrow the normal range and increase the discriminating ability of scanning laser polarimetry between normal and disease. However, modulation is less affected, and the modulation parameters may thus prove more useful for distinguishing between normal and glaucoma.

Entities:  

Mesh:

Year:  2003        PMID: 12689893     DOI: 10.1016/S0161-6420(02)01899-7

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  21 in total

1.  Enhanced corneal compensation for scanning laser polarimetry on eyes with atypical polarisation pattern.

Authors:  M Tóth; G Holló
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

2.  Scanning laser polarimetry with variable and enhanced corneal compensation in normal and glaucomatous eyes.

Authors:  Mitra Sehi; Delia C Guaqueta; William J Feuer; David S Greenfield
Journal:  Am J Ophthalmol       Date:  2006-10-25       Impact factor: 5.258

3.  Relationship between foveal birefringence and visual acuity in neovascular age-related macular degeneration.

Authors:  A Weber; A E Elsner; M Miura; S Kompa; M C Cheney
Journal:  Eye (Lond)       Date:  2006-01-06       Impact factor: 3.775

4.  An enhancement module to improve the atypical birefringence pattern using scanning laser polarimetry with variable corneal compensation.

Authors:  M Sehi; D C Guaqueta; D S Greenfield
Journal:  Br J Ophthalmol       Date:  2006-02-15       Impact factor: 4.638

5.  GDx-VCC performance in discriminating normal from glaucomatous eyes with early visual field loss.

Authors:  Stefano Da Pozzo; Mirko Fuser; Odilla Vattovani; Giuseppe Di Stefano; Giuseppe Ravalico
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-11-16       Impact factor: 3.117

6.  Adaptive optics imaging of healthy and abnormal regions of retinal nerve fiber bundles of patients with glaucoma.

Authors:  Monica F Chen; Toco Y P Chui; Paula Alhadeff; Richard B Rosen; Robert Ritch; Alfredo Dubra; Donald C Hood
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-01-08       Impact factor: 4.799

7.  Imaging of the optic nerve and retinal nerve fiber layer: an essential part of glaucoma diagnosis and monitoring.

Authors:  Jacek Kotowski; Gadi Wollstein; Hiroshi Ishikawa; Joel S Schuman
Journal:  Surv Ophthalmol       Date:  2013-10-16       Impact factor: 6.048

8.  Scanning laser polarimetry with variable corneal compensation and detection of glaucomatous optic neuropathy.

Authors:  Stefano Da Pozzo; Pierluigi Iacono; Roberta Marchesan; Anna Fantin; Giuseppe Ravalico
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-09       Impact factor: 3.117

9.  Relative course of retinal nerve fiber layer birefringence and thickness and retinal function changes after optic nerve transection.

Authors:  Brad Fortune; Grant A Cull; Claude F Burgoyne
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-06-19       Impact factor: 4.799

10.  Retinal nerve fibre layer assessment in myopic glaucomatous eyes: comparison of GDx variable corneal compensation with GDx enhanced corneal compensation.

Authors:  S Morishita; T Tanabe; S Yu; M Hangai; T Ojima; H Aikawa; N Yoshimura
Journal:  Br J Ophthalmol       Date:  2008-07-29       Impact factor: 4.638

View more