Efficacy and cost of home-initiated auto-nCPAP versus conventional nCPAP.

Carole Planès1, Marie-Pia D'Ortho, Arlette Foucher, Malika Berkani, Karl Leroux, Mohamed Essalhi, Christophe Delclaux, Maria-Antonia Quera-Salva, Frédéric Lofaso.   

Abstract

STUDY
OBJECTIVES: To compare in a multicenter prospective study the efficacy and cost of conventional nasal continuous positive airway pressure (nCPAP) initiated at the sleep laboratory versus auto-nCPAP initiated at home.
DESIGN: Patients with severe obstructive sleep apnea syndrome (OSAS) were randomized to treatment with either the REM+ auto device in constant mode at the effective pressure determined by titration at the sleep laboratory (n=17) or the REM+ auto device in automatic mode initiated at the patients home by a nurse (n=18). After 2 months, the efficacy and cost of nCPAP therapy and the time from diagnosis to nCPAP were evaluated. All values are reported as means +/- SD. PATIENTS: Thirty-five subjects with newly diagnosed OSAS (8 women and 27 men, mean age: 54.3 +/- 10.6 years, apnea-hypopnea index (AHI) 58.1 +/- 14.0 h(-1)).
INTERVENTIONS: N/A. MEASUREMENTS AND
RESULTS: Both treatments were used properly and induced similar decreases in the AHI (7.6 +/- 6.9 vs. 10.4 +/ -12.5 h(-1) for auto-nCPAP and conventional nCPAP, respectively; NS) and Epworth Sleepiness score (from 15.5 +/- 4.7 to 7.5 +/- 3.4 vs. 14.7 +/- 3.9 to 7.6 +/- 3.4 for auto-nCPAP and conventional nCPAP, respectively; NS). With auto-nCPAP initiated at home, the time from diagnosis to final adjustment of nCPAP was shorter (16.3 +/- 5.0 vs. 47.2 +/- 46.5 days with conventional nCPAP, P < 0.02) and the cost was lower (1,263 +/- 352 vs. 1720+/-455 E, respectively; P < 0.05).
CONCLUSIONS: Treatment of OSAS with auto-nCPAP initiated at home is effective and reliable and reduces the time from diagnosis to therapy and the cost of treatment.

Entities:  

Mesh:

Year:  2003        PMID: 12683473     DOI: 10.1093/sleep/26.2.156

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  17 in total

Review 1.  New developments in the use of positive airway pressure for obstructive sleep apnea.

Authors:  Lucas M Donovan; Schafer Boeder; Atul Malhotra; Sanjay R Patel
Journal:  J Thorac Dis       Date:  2015-08       Impact factor: 2.895

2.  [Recommendations for ambulatory polygraphy by the Austrian Pneumology Society].

Authors:  Martin Huppmann; Wolfgang Schreiber; Gernot Moder; Boris Fugger; Georg Kapfhammer; Leopold Stiebellehner
Journal:  Wien Klin Wochenschr       Date:  2007       Impact factor: 1.704

3.  Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment.

Authors:  Susheel P Patil; Indu A Ayappa; Sean M Caples; R Joh Kimoff; Sanjay R Patel; Christopher G Harrod
Journal:  J Clin Sleep Med       Date:  2019-02-15       Impact factor: 4.062

4.  Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea.

Authors:  S D West; D R Jones; J R Stradling
Journal:  Thorax       Date:  2005-10-27       Impact factor: 9.139

5.  Effect of air leak on the performance of auto-PAP devices: a bench study.

Authors:  Dale Coller; Dawn Stanley; Sairam Parthasarathy
Journal:  Sleep Breath       Date:  2005-12       Impact factor: 2.816

Review 6.  Effect of automatic versus fixed continuous positive airway pressure for the treatment of obstructive sleep apnea: an up-to-date meta-analysis.

Authors:  Ting Xu; Taoping Li; Dongning Wei; Yuan Feng; Lewu Xian; Haiqing Wu; Jian Xu
Journal:  Sleep Breath       Date:  2011-12-03       Impact factor: 2.816

7.  Upper airway collapsibility in patients with OSA treated with continuous positive airway pressure: a retrospective preliminary study.

Authors:  Marcello Bosi; Serena Incerti Parenti; Andrea Fiordelli; Venerino Poletti; Giulio Alessandri-Bonetti
Journal:  J Clin Sleep Med       Date:  2020-11-15       Impact factor: 4.062

8.  Autotitrating CPAP as a Tool for CPAP Initiation for Children.

Authors:  Rebecca Mihai; Moya Vandeleur; Sally Pecoraro; Margot J Davey; Gillian M Nixon
Journal:  J Clin Sleep Med       Date:  2017-05-15       Impact factor: 4.062

9.  An empirical continuous positive airway pressure trial for suspected obstructive sleep apnea.

Authors:  Robert P Skomro; David J Cotton; John A Gjevre; Vaneeta K Grover; Brian D McNab; John K Reid; Heather A Ward
Journal:  Can Respir J       Date:  2007-04       Impact factor: 2.409

10.  Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

Authors:  Timothy I Morgenthaler; R Nisha Aurora; Terry Brown; Rochelle Zak; Cathy Alessi; Brian Boehlecke; Andrew L Chesson; Leah Friedman; Vishesh Kapur; Rama Maganti; Judith Owens; Jeffrey Pancer; Todd J Swick
Journal:  Sleep       Date:  2008-01       Impact factor: 5.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.