Literature DB >> 17464380

An empirical continuous positive airway pressure trial for suspected obstructive sleep apnea.

Robert P Skomro1, David J Cotton, John A Gjevre, Vaneeta K Grover, Brian D McNab, John K Reid, Heather A Ward.   

Abstract

BACKGROUND: Standard practice in obstructive sleep apnea (OSA) management requires that a positive diagnostic, overnight polysomnography (PSG) test be obtained before initiating treatment. However, long waiting times due to lack of access to PSG testing facilities may delay the initiation of definitive treatment for OSA.
OBJECTIVES: To evaluate the response of patients who had a high clinical suspicion for OSA and who were waiting for a PSG test to an empirical continuous positive airway pressure (CPAP) trial.
METHODS: A retrospective study of all patients who had been offered empirical CPAP therapy for suspected OSA was conducted. After outpatient assessment, 183 patients with a high pretest probability of having OSA began empirical CPAP testing using an arbitrary CPAP pressure. The presence of OSA, the accuracy of empirical CPAP pressure prescription, the adherence to empirical CPAP and the improvement in daytime somnolence were evaluated at the time of PSG.
RESULTS: Of 183 patients on a CPAP trial, 91% had OSA, which was at least moderate (more than 15 apneas and hypopneas per hour of sleep) in 75% of the patients. Eighty per cent of the patients had significant daytime somnolence (Epworth Sleepiness Scale [ESS] greater than 10, mean +/- SD ESS 14+/-5), which improved with CPAP (ESS 9.0+/-5, P<0.01). In 40% of the patients, the arbitrary CPAP pressure was lower than that determined by manual titration. Adherence to a trial of CPAP (longer than 2 h/night) predicted OSA with a sensitivity of 82% and a specificity of 41%; the positive and negative predictive values were 92% and 22%, respectively.
CONCLUSIONS: At the time of PSG testing, OSA was present in 91% of the patients who had received empirical CPAP. An empirical CPAP provided satisfactory interim treatment for excessive somnolence, despite the fact that the CPAP pressure was suboptimal in 40% of the patients.

Entities:  

Mesh:

Year:  2007        PMID: 17464380      PMCID: PMC2676837          DOI: 10.1155/2007/397984

Source DB:  PubMed          Journal:  Can Respir J        ISSN: 1198-2241            Impact factor:   2.409


  38 in total

Review 1.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

Authors: 
Journal:  Sleep       Date:  1999-08-01       Impact factor: 5.849

2.  Arbitrary-pressure continuous positive airway pressure for obstructive sleep apnea syndrome.

Authors:  Craig A Hukins
Journal:  Am J Respir Crit Care Med       Date:  2004-11-24       Impact factor: 21.405

Review 3.  Sleep.7: positive airway pressure therapy for obstructive sleep apnoea/hypopnoea syndrome.

Authors:  P Gordon; M H Sanders
Journal:  Thorax       Date:  2005-01       Impact factor: 9.139

4.  Development of a disease-specific health-related quality of life questionnaire for sleep apnea.

Authors:  W W Flemons; M A Reimer
Journal:  Am J Respir Crit Care Med       Date:  1998-08       Impact factor: 21.405

5.  Practice parameters for the indications for polysomnography and related procedures. Polysomnography Task Force, American Sleep Disorders Association Standards of Practice Committee.

Authors: 
Journal:  Sleep       Date:  1997-06       Impact factor: 5.849

6.  Health care utilization in males with obstructive sleep apnea syndrome two years after diagnosis and treatment.

Authors:  A Bahammam; K Delaive; J Ronald; J Manfreda; L Roos; M H Kryger
Journal:  Sleep       Date:  1999-09-15       Impact factor: 5.849

7.  Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial.

Authors:  C Jenkinson; R J Davies; R Mullins; J R Stradling
Journal:  Lancet       Date:  1999-06-19       Impact factor: 79.321

8.  Clinical usefulness of home oximetry compared with polysomnography for assessment of sleep apnea.

Authors:  William A Whitelaw; Rollin F Brant; W Ward Flemons
Journal:  Am J Respir Crit Care Med       Date:  2004-10-14       Impact factor: 21.405

9.  Relation of sleepiness to respiratory disturbance index: the Sleep Heart Health Study.

Authors:  D J Gottlieb; C W Whitney; W H Bonekat; C Iber; G D James; M Lebowitz; F J Nieto; C E Rosenberg
Journal:  Am J Respir Crit Care Med       Date:  1999-02       Impact factor: 21.405

10.  Evidence of the effectiveness of continuous positive airway pressure in the treatment of sleep apnea/hypopnea syndrome.

Authors:  E Ballester; J R Badia; L Hernández; E Carrasco; J de Pablo; C Fornas; R Rodriguez-Roisin; J M Montserrat
Journal:  Am J Respir Crit Care Med       Date:  1999-02       Impact factor: 21.405

View more
  5 in total

1.  Can CPAP be indicated in adult patients with suspected obstructive sleep apnea only on the basis of clinical data?

Authors:  Carlos Alberto Nigro; Eduardo Dibur; María Rosario Aragone; Eduardo Borsini; Glenda Ernst; Facundo Nogueria
Journal:  Sleep Breath       Date:  2015-06-04       Impact factor: 2.816

2.  Decision Modeling in Sleep Apnea: The Critical Roles of Pretest Probability, Cost of Untreated Obstructive Sleep Apnea, and Time Horizon.

Authors:  Marilyn Moro; M Brandon Westover; Jessica Kelly; Matt T Bianchi
Journal:  J Clin Sleep Med       Date:  2016-03       Impact factor: 4.062

Review 3.  Mathematical Equations to Predict Positive Airway Pressures for Obstructive Sleep Apnea: A Systematic Review.

Authors:  Macario Camacho; Muhammad Riaz; Armin Tahoori; Victor Certal; Clete A Kushida
Journal:  Sleep Disord       Date:  2015-07-30

4.  Determination of equation for estimating continuous positive airway pressure in patients with obstructive sleep apnea for the Indian population.

Authors:  Latha Sarma; Nandan Putti; Kapil Alias; Mohit Chilana
Journal:  Lung India       Date:  2020 Sep-Oct

5.  Polysomnographic evaluation of obstructive sleep apnea treatment with fixed pressure CPAP determined by formula.

Authors:  Danilo M Sá; Elcio O Vianna
Journal:  Sleep Breath       Date:  2022-03-04       Impact factor: 2.816

  5 in total