Effect of air leak on the performance of auto-PAP devices: a bench study.

Dale Coller1, Dawn Stanley, Sairam Parthasarathy.   

Abstract

Automatic positive airway pressure (auto-PAP) devices, used in the treatment of patients with obstructive sleep apnea (OSA), may not function optimally in the presence of an air leak. We set out to determine the magnitude of air leak that prevents auto-PAP devices from responding to respiratory events of OSA in a bench model. We simulated apnea, flow limitation, obstructive hypopnea, nonobstructive hypopnea, and snoring events of OSA with an artificial airway and a loudspeaker in a bench model connected to a commercially available auto-PAP device. Four auto-PAP devices were tested, but two of the "older-generation" devices (Tranquility and Virtuoso) did not respond to events of OSA that involved changes in flow contour; hence, we studied the effects of air leak and humidifier in the two "newer-generation" auto-PAP devices only (GoodKnight 418P, Autoset-T). When the air leak was progressively increased from baseline levels recommended by the manufacturer to levels seen clinically--5 to 7, 10, and 30 l/min--the GoodKnight 418P decreased pressure response by 56% (5.6+/-1.8 cm H(2)O, p=0.04). The pressure response of the Autoset-T, however, did not change from baseline during similar levels of air leak. The GoodKnight performed appropriately when the air leak was within 20 l/min, but the corresponding value for the Autoset was higher at 50 l/min. For both devices combined, air leak caused the pressure to drop between the device and the airway: 2.8+/-0.3 cm H(2)O at 30 l/min of air leak (p<0.001). Air leaks cause auto-PAP devices to underestimate the pressure required to treat events of OSA and to overestimate the pressure delivered at the upper airway. Physicians should be aware of performance limitations of auto-PAP devices in the presence of an air leak.

Entities:  

Mesh:

Year:  2005        PMID: 16273421     DOI: 10.1007/s11325-005-0032-z

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  26 in total

Review 1.  Intelligent CPAP systems: clinical experience.

Authors:  H Teschler; M Berthon-Jones
Journal:  Thorax       Date:  1998-10       Impact factor: 9.139

2.  Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure.

Authors:  C A Massie; R W Hart; K Peralez; G N Richards
Journal:  Chest       Date:  1999-08       Impact factor: 9.410

3.  Appearance of central apnoea in a patient treated by auto-CPAP for obstructive sleep apnoea.

Authors:  A Boudewyns; P Van de Heyning; W De Backer
Journal:  Respir Med       Date:  1998-06       Impact factor: 3.415

4.  Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine report.

Authors:  Michael Littner; Maxwell Hirshkowitz; David Davila; W McDowell Anderson; Clete A Kushida; B Tucker Woodson; Stephen F Johnson; S Wise Merrill
Journal:  Sleep       Date:  2002-03-15       Impact factor: 5.849

5.  Indications and standards for use of nasal continuous positive airway pressure (CPAP) in sleep apnea syndromes. American Thoracic Society. Official statement adopted March 1944.

Authors: 
Journal:  Am J Respir Crit Care Med       Date:  1994-12       Impact factor: 21.405

6.  Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome.

Authors:  P Lloberes; E Ballester; J M Montserrat; E Botifoll; A Ramirez; A Reolid; C Gistau; R Rodriguez-Roisin
Journal:  Am J Respir Crit Care Med       Date:  1996-12       Impact factor: 21.405

7.  A long-term randomized, cross-over comparison of auto-titrating and standard nasal continuous airway pressure.

Authors:  D W Hudgel; C Fung
Journal:  Sleep       Date:  2000-08-01       Impact factor: 5.849

8.  Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares.

Authors:  C E Sullivan; F G Issa; M Berthon-Jones; L Eves
Journal:  Lancet       Date:  1981-04-18       Impact factor: 79.321

9.  Auto-titrating versus standard continuous positive airway pressure for the treatment of obstructive sleep apnea: results of a meta-analysis.

Authors:  Najib T Ayas; Sanjay R Patel; Atul Malhotra; Michael Schulzer; Mark Malhotra; David Jung; John Fleetham; David P White
Journal:  Sleep       Date:  2004-03-15       Impact factor: 5.849

10.  Randomized short-term trial of two autoCPAP devices versus fixed continuous positive airway pressure for the treatment of sleep apnea.

Authors:  Oliver Senn; Thomas Brack; Felix Matthews; Erich W Russi; Konrad E Bloch
Journal:  Am J Respir Crit Care Med       Date:  2003-10-02       Impact factor: 21.405

View more
  15 in total

1.  CON: thoughtful steps informed by more comparative effectiveness research is needed in home testing.

Authors:  Sairam Parthasarathy
Journal:  J Clin Sleep Med       Date:  2013-01-15       Impact factor: 4.062

2.  Effect of addition of chin strap on PAP compliance, nightly duration of use, and other factors.

Authors:  Shelley R Knowles; Daniel T O'Brien; Shiling Zhang; Anupama Devara; James A Rowley
Journal:  J Clin Sleep Med       Date:  2014-04-15       Impact factor: 4.062

3.  Advances in Positive Airway Pressure Treatment Modalities for Hypoventilation Syndromes.

Authors:  Dan Combs; Safal Shetty; Sairam Parthasarathy
Journal:  Sleep Med Clin       Date:  2014-09

4.  Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak.

Authors:  Jessie P Bakker; Alister M Neill; Angela J Campbell
Journal:  Sleep Breath       Date:  2011-07-29       Impact factor: 2.816

5.  Air leak is associated with poor adherence to autoPAP therapy.

Authors:  Alexandra Valentin; Shyam Subramanian; Stuart F Quan; Richard B Berry; Sairam Parthasarathy
Journal:  Sleep       Date:  2011-06-01       Impact factor: 5.849

6.  APAP and Alternative Titration Methods.

Authors:  Omer Ahmed; Sairam Parthasarathy
Journal:  Sleep Med Clin       Date:  2010-09-01

Review 7.  CPAP and bi-level PAP therapy: new and established roles.

Authors:  Andreea Antonescu-Turcu; Sairam Parthasarathy
Journal:  Respir Care       Date:  2010-09       Impact factor: 2.258

8.  Sleep and non-invasive ventilation in patients with chronic respiratory insufficiency.

Authors:  Cristina Ambrogio; Xazmin Lowman; Ming Kuo; Joshua Malo; Anil R Prasad; Sairam Parthasarathy
Journal:  Intensive Care Med       Date:  2008-09-16       Impact factor: 17.440

9.  Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model.

Authors:  Kaixian Zhu; Sami Aouf; Gabriel Roisman; Pierre Escourrou
Journal:  J Clin Sleep Med       Date:  2016-03       Impact factor: 4.062

10.  Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

Authors:  Hsin-Chia Carol Huang; David R Hillman; Nigel McArdle
Journal:  Sleep       Date:  2012-09-01       Impact factor: 5.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.