Computerized scheme for determination of the likelihood measure of malignancy for pulmonary nodules on low-dose CT images.

Masahito Aoyama1, Qiang Li, Shigehiko Katsuragawa, Feng Li, Shusuke Sone, Kunio Doi.   

Abstract

An automated computerized scheme has been developed for determination of the likelihood measure of malignancy of pulmonary nodules on low-dose helical CT (LDCT) images. Our database consisted of 76 primary lung cancers (147 slices) and 413 benign nodules (576 slices). With this automated computerized scheme, the location of a nodule was first indicated by a radiologist. The outline of the nodule was segmented automatically by use of a dynamic programming technique. Various objective features on the nodules were determined by use of outline analysis and image analysis, and the likelihood measure of malignancy was determined by use of linear discriminant analysis (LDA). The effect of many different combinations of features and the performance of LDA in distinguishing benign nodules from malignant ones were evaluated by means of receiver operating characteristic (ROC) analysis. The Az value (area under the ROC curve) obtained by the computerized scheme in distinguishing benign nodules from malignant ones was 0.828 when a single slice was employed for each of the nodules. However, the Az value was improved to 0.846 when multiple slices were used for determination of the likelihood measure of malignancy. The Az values obtained by the computerized scheme on LDCT images were significantly greater than the Az value of 0.70, which was obtained from our previous observer studies by radiologists in distinguishing benign nodules from malignant ones on LDCT images. The automated computerized scheme for determination of the likelihood measure of malignancy would be useful in assisting radiologists to distinguish between benign and malignant pulmonary nodules on LDCT images.

Entities:  

Mesh:

Year:  2003        PMID: 12674239     DOI: 10.1118/1.1543575

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  A computerized scheme for lung nodule detection in multiprojection chest radiography.

Authors:  Wei Guo; Qiang Li; Sarah J Boyce; H Page McAdams; Junji Shiraishi; Kunio Doi; Ehsan Samei
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Automated lung segmentation in digital chest tomosynthesis.

Authors:  Jiahui Wang; James T Dobbins; Qiang Li
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Improved pulmonary nodule classification utilizing quantitative lung parenchyma features.

Authors:  Samantha K N Dilger; Johanna Uthoff; Alexandra Judisch; Emily Hammond; Sarah L Mott; Brian J Smith; John D Newell; Eric A Hoffman; Jessica C Sieren
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-01

4.  Computer-aided diagnosis of pulmonary nodules on CT scans: segmentation and classification using 3D active contours.

Authors:  Ted W Way; Lubomir M Hadjiiski; Berkman Sahiner; Heang-Ping Chan; Philip N Cascade; Ella A Kazerooni; Naama Bogot; Chuan Zhou
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

5.  Improvement of bias and generalizability for computer-aided diagnostic schemes.

Authors:  Qiang Li
Journal:  Comput Med Imaging Graph       Date:  2007-03-23       Impact factor: 4.790

Review 6.  Recent progress in computer-aided diagnosis of lung nodules on thin-section CT.

Authors:  Qiang Li
Journal:  Comput Med Imaging Graph       Date:  2007-03-21       Impact factor: 4.790

7.  Reliable evaluation of performance level for computer-aided diagnostic scheme.

Authors:  Qiang Li
Journal:  Acad Radiol       Date:  2007-08       Impact factor: 3.173

Review 8.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

9.  Computerized detection of lung nodules in thin-section CT images by use of selective enhancement filters and an automated rule-based classifier.

Authors:  Qiang Li; Feng Li; Kunio Doi
Journal:  Acad Radiol       Date:  2008-02       Impact factor: 3.173

Review 10.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more