Literature DB >> 12673170

A method for attenuation and scatter correction of brain SPECT based on computed tomography images.

A Larsson1, L Johansson, T Sundström, K Riklund Ahlström.   

Abstract

A method for attenuation and scatter correction of brain single photon emission computed tomography (SPECT) is described where computed tomography (CT) images of the brain are used for the calculation of attenuation maps. The method is evaluated for the substance 99mTc hexamethylpropylene amine oxime. A transmission dependent scatter correction is utilized and is based on ray sums calculated through the attenuation map. A method based on external markers is used to align the SPECT and CT image volumes. The markers need only to be present during the SPECT acquisition since the corresponding landmarks can be found without markers on the CT images. The mismatching has been investigated for five patients who have undergone both a CT examination and a SPECT examination with markers. Twelve individuals from the staff have pointed out the landmarks on the CT images, with an average standard deviation of 3.4 mm. Reconstructions with an attenuation map shifted the corresponding 95% confidence interval have been performed to obtain an estimation of the quantitative uncertainty caused by the mismatching, and quantitative errors of up to 6.3% have been measured. At present the method is probably most useful when groups of patients are studied.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12673170     DOI: 10.1097/00006231-200304000-00011

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  7 in total

1.  Attenuation correction for lung SPECT: evidence of need and validation of an attenuation map derived from the emission data.

Authors:  Margarita Núñez; Vineet Prakash; Ricardo Vila; Fernando Mut; Omar Alonso; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-02-24       Impact factor: 9.236

2.  Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality.

Authors:  Dale L Bailey; Kathy P Willowson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-09-14       Impact factor: 9.236

Review 3.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

4.  Individual voxelwise dosimetry of targeted 90Y-labelled substance P radiotherapy for malignant gliomas.

Authors:  Stefan Kneifel; Peter Bernhardt; Helena Uusijärvi; Stephan Good; Ludwig Plasswilm; Carlos Buitrago-Téllez; Jan Müller-Brand; Helmut Mäcke; Adrian Merlo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-31       Impact factor: 9.236

5.  Altered cerebral blood flow in chronic neck pain patients but not in whiplash patients: a 99mTc-HMPAO rCBF study.

Authors:  Torbjörn Sundström; Michel Guez; Christer Hildingsson; Göran Toolanen; Lars Nyberg; Katrine Riklund
Journal:  Eur Spine J       Date:  2006-04-14       Impact factor: 3.134

6.  CT-based quantitative SPECT for the radionuclide ²⁰¹Tl: experimental validation and a standardized uptake value for brain tumour patients.

Authors:  Kathy Willowson; Dale Bailey; Geoff Schembri; Clive Baldock
Journal:  Cancer Imaging       Date:  2012       Impact factor: 3.909

7.  Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom.

Authors:  Mana Akamatsu; Yasuo Yamashita; Go Akamatsu; Yuji Tsutsui; Nobuyoshi Ohya; Yasuhiko Nakamura; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2014
  7 in total