PURPOSE: The aim of our study was to investigate the importance of attenuation correction (AC) in reconstructed and reprojected images on lung SPECT studies. METHODS: Simulation studies were undertaken to evaluate the influence of AC on defect-to-normal ratios (D/N), to demonstrate the influence of errors in the correction map values and to detect lung boundaries used for AC. The use of a synthetic map (SM) for AC of the clinical data was also evaluated and the results compared with those obtained with data derived from CT (CTM). Additionally, the role of AC in reprojected SPECT data was assessed and level of noise on the 'planar-like' images was measured. RESULTS: Phantom studies showed that AC markedly affects the D/N ratio. However, variations in micro values typical of those found in clinical studies resulted in relatively small changes in results. Eroded and dilated conditions did not cause any significant effect on D/N. The level of noise in the reprojected images is reduced in comparison with real planar data. Clinical SPECT/CT data reconstructed with AC using CTM and SM showed an excellent correlation between the two methods. CONCLUSION: AC improves D/N in lung SPECT studies, thus potentially enhancing the diagnostic capability of the method. The use of a synthetic map for AC is feasible, avoiding the need for an additional procedure and the increased radiation dose involved. Planar-like images generated from reprojected SPECT data are well matched to normal planar images provided AC is performed and attenuation included in the reprojection.
PURPOSE: The aim of our study was to investigate the importance of attenuation correction (AC) in reconstructed and reprojected images on lung SPECT studies. METHODS: Simulation studies were undertaken to evaluate the influence of AC on defect-to-normal ratios (D/N), to demonstrate the influence of errors in the correction map values and to detect lung boundaries used for AC. The use of a synthetic map (SM) for AC of the clinical data was also evaluated and the results compared with those obtained with data derived from CT (CTM). Additionally, the role of AC in reprojected SPECT data was assessed and level of noise on the 'planar-like' images was measured. RESULTS: Phantom studies showed that AC markedly affects the D/N ratio. However, variations in micro values typical of those found in clinical studies resulted in relatively small changes in results. Eroded and dilated conditions did not cause any significant effect on D/N. The level of noise in the reprojected images is reduced in comparison with real planar data. Clinical SPECT/CT data reconstructed with AC using CTM and SM showed an excellent correlation between the two methods. CONCLUSION:AC improves D/N in lung SPECT studies, thus potentially enhancing the diagnostic capability of the method. The use of a synthetic map for AC is feasible, avoiding the need for an additional procedure and the increased radiation dose involved. Planar-like images generated from reprojected SPECT data are well matched to normal planar images provided AC is performed and attenuation included in the reprojection.
Authors: Anna Celler; Katherine L Dixon; Zheng Chang; Stephan Blinder; John Powe; Ronald Harrop Journal: J Nucl Med Date: 2005-02 Impact factor: 10.057
Authors: R D Hull; J Hirsh; C J Carter; G E Raskob; G J Gill; R M Jay; J R Leclerc; M David; G Coates Journal: Chest Date: 1985-12 Impact factor: 9.410
Authors: Mahsa Torkaman; Jaewon Yang; Luyao Shi; Rui Wang; Edward J Miller; Albert J Sinusas; Chi Liu; Grant T Gullberg; Youngho Seo Journal: Proc SPIE Int Soc Opt Eng Date: 2021-02-15
Authors: Ashequr Rahman; Yansong Zhu; Eric Clarkson; Matthew A Kupinski; Eric C Frey; Abhinav K Jha Journal: Inverse Probl Date: 2020-08-20 Impact factor: 2.407
Authors: Mahsa Torkaman; Jaewon Yang; Luyao Shi; Rui Wang; Edward J Miller; Albert J Sinusas; Chi Liu; Grant T Gullberg; Youngho Seo Journal: IEEE Trans Radiat Plasma Med Sci Date: 2021-12-24
Authors: Jaewon Yang; Luyao Shi; Rui Wang; Edward J Miller; Albert J Sinusas; Chi Liu; Grant T Gullberg; Youngho Seo Journal: J Nucl Med Date: 2021-02-26 Impact factor: 11.082