Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time.

Frederick Chee1, Tyrone Fernando, P Vernon van Heerden.   

Abstract

A study was conducted to determine if continuous subcutaneous glucose monitoring (from MiniMed CGMS) could be used in real-time to control blood sugar level (BSL) in patients with critical illness. A closed-loop control system was constructed to use CGMS in a real-time manner, coupled with a proportional integral (PI) control algorithm based on a sliding scale approach, for automatic intravenous infusion of insulin to patients. A total of five subjects with high BSL (> 10 mmol/L) participated in formal studies of the closed-loop control system. Subjects were recruited from critically ill patients in the intensive care unit (ICU) after informed consent was obtained. Error grid analysis showed that 64.6% of the BSL readings as determined in real time using CGMS sensor, when compared to conventional BSL measurements on blood drawn from an arterial line, was clinically accurate (i.e., < 20% deviation from glucometer value). In the five patients who underwent closed-loop control, the controller managed to control only one patient's glycaemia without any manual intervention. Manual intervention was required due to the real-time sensor reading deviating more than 20% from the glucometer value, and also as a safety mechanism. Test on equality of mean and variance for BSL attained prior to, during, and post trial showed that the controller's performance was comparable to manual control. We conclude that the automatic sliding scale approach of closed-loop BSL control is feasible in patients in intensive care. More work is needed in the refinement of the algorithm and the improvement of real-time sensor accuracy.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12670018     DOI: 10.1109/titb.2003.808509

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  27 in total

1.  A switching control strategy for the attenuation of blood glucose disturbances.

Authors:  Mihalis G Markakis; Georgios D Mitsis; George P Papavassilopoulos; Petros A Ioannou; Vasilis Z Marmarelis
Journal:  Optim Control Appl Methods       Date:  2011       Impact factor: 2.530

2.  Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring.

Authors:  Ulrike Holzinger; Joanna Warszawska; Reinhard Kitzberger; Harald Herkner; Philipp G H Metnitz; Christian Madl
Journal:  Intensive Care Med       Date:  2009-04-07       Impact factor: 17.440

Review 3.  Essential elements of the native glucoregulatory system, which, if appreciated, may help improve the function of glucose controllers in the intensive care unit setting.

Authors:  Leon DeJournett
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

Review 4.  Diabetes Technology in the Inpatient Setting for Management of Hyperglycemia.

Authors:  Georgia M Davis; Rodolfo J Galindo; Alexandra L Migdal; Guillermo E Umpierrez
Journal:  Endocrinol Metab Clin North Am       Date:  2020-03       Impact factor: 4.741

5.  Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units.

Authors:  Atoosa Rabiee; Virginia Andreasik; Rania Abu-Hamdah; Panagis Galiatsatos; Zeina Khouri; B Robert Gibson; Dana K Andersen; Dariush Elahi
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

6.  In silico testing--impact on the progress of the closed loop insulin infusion for critically ill patients project.

Authors:  Malgorzata E Wilinska; Ludovic J Chassin; Roman Hovorka
Journal:  J Diabetes Sci Technol       Date:  2008-05

Review 7.  Clinical need for continuous glucose monitoring in the hospital.

Authors:  Jeffrey I Joseph; Brian Hipszer; Boris Mraovic; Inna Chervoneva; Mark Joseph; Zvi Grunwald
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

8.  Pilot study of the SPRINT glycemic control protocol in a Hungarian medical intensive care unit.

Authors:  Balazs Benyo; Attila Illyés; Noémi Szabó Némedi; Aaron J Le Compte; Attila Havas; Levente Kovacs; Liam Fisk; Geoffrey M Shaw; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

9.  Real-time state estimation and long-term model adaptation: a two-sided approach toward personalized diagnosis of glucose and insulin levels.

Authors:  Claudia Eberle; Christoph Ament
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

10.  Overview of glycemic control in critical care: relating performance and clinical results.

Authors:  J Geoffrey Chase; Christopher E Hann; Geoffrey M Shaw; Jason Wong; Jessica Lin; Thomas Lotz; Aaron Lecompte; Timothy Lonergan
Journal:  J Diabetes Sci Technol       Date:  2007-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.