Literature DB >> 12666225

The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting.

N J Raine-Fenning1, J S Clewes, N R Kendall, A K Bunkheila, B K Campbell, I R Johnson.   

Abstract

OBJECTIVES: The primary aim of this validation study was to determine the interobserver reliability and validity of measurements of phantom objects of known volume using conventional and rotational techniques of volume calculation according to measurement technique.
METHODS: Two observers each acquired a single three-dimensional ultrasound dataset of three water-filled objects of different size and shape. The same two observers measured all six datasets using both the conventional technique and the newer rotational technique (Virtual Organ Computer-aided AnaLysis, VOCAL( trade mark )) of volume calculation. Reliability was assessed by calculating intraclass correlation coefficients (ICC) and validity by examining the percentage difference from the 'true' volume, as determined by a water displacement technique, by the limits of agreement method.
RESULTS: All of the techniques were highly reliable (ICC: 0.9962-0.9997) and valid to within 4% of the 'true' volumes. There were no significant differences in reliability according to measurement plane or between observers. Measurements made with the 6 degrees rotation step were significantly more reliable than those made by all other techniques with the exception of the 9 degrees rotation step (P < 0.05) and significantly more valid than those made with the 30 degrees rotation step or conventional technique (P < 0.05).
CONCLUSIONS: Volume calculation in the in vitro setting is both reliable and valid but is dependent upon the technique applied, with rotational measurements of volume proving superior to conventional techniques. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 12666225     DOI: 10.1002/uog.61

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  24 in total

1.  Reproducibility of fetal heart volume by 3D-sonography using the XI VOCAL method.

Authors:  Enoch Q Barreto; Hérbene F Milani; Edward Araujo Júnior; Karina K Haratz; Liliam C Rolo; Luciano M Nardozza; Hélio A Guimarães Filho; Antonio F Moron
Journal:  Cardiovasc Ultrasound       Date:  2010-05-12       Impact factor: 2.062

2.  The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).

Authors:  J P Kusanovic; J K Nien; L F Gonçalves; J Espinoza; W Lee; M Balasubramaniam; E Soto; O Erez; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2008-02       Impact factor: 7.299

3.  Intra- and interobserver agreement for fetal cerebral measurements in 3D-ultrasonography.

Authors:  Maria E W A Albers; Erato T I A Buisman; René S Kahn; Arie Franx; N Charlotte Onland-Moret; Roel de Heus
Journal:  Hum Brain Mapp       Date:  2018-04-10       Impact factor: 5.038

4.  Endometrial thickness and volume by three-dimensional ultrasound one week after embryo transfer to detect pregnancy.

Authors:  Wellington de Paula Martins; Rui Alberto Ferriani; Rosana Maria dos Reis; Carolina Oliveira Nastri; Francisco Mauad Filho
Journal:  J Assist Reprod Genet       Date:  2006-09-05       Impact factor: 3.412

5.  Multiview Contouring for Breast Tumor on Magnetic Resonance Imaging.

Authors:  Dar-Ren Chen; Yao-Wen Chang; Hwa-Koon Wu; Wei-Chung Shia; Yu-Len Huang
Journal:  J Digit Imaging       Date:  2019-10       Impact factor: 4.056

6.  Endometrial thickness and volume by three-dimensional ultrasound one week after embryo transfer to detect pregnancy.

Authors:  Wellington Paula Martins; Rui Alberto Ferriani; Rosana Maria dos Reis; Carolina Oliveira Nastri; Francisco Mauad Filho
Journal:  J Assist Reprod Genet       Date:  2007-03-08       Impact factor: 3.412

7.  Fetal volume measurements with three dimensional ultrasound in the first trimester of pregnancy, related to pregnancy outcome, a prospective cohort study.

Authors:  Nicol A C Smeets; Marc Prudon; Bjorn Winkens; S Guid Oei
Journal:  BMC Pregnancy Childbirth       Date:  2012-05-28       Impact factor: 3.007

8.  Assessment of renal volume by three-dimensional ultrasonography in pregnant bitches: an experimental study using virtual organ computer-aided analysis.

Authors:  Débora Sartori Mendonça; Rafael Fontoura Fernandes Moron; André Luiz Louzada Maldonado; Edward Araujo Júnior; Luciano Marcondes Machado Nardozza; Antonio Fernandes Moron
Journal:  BMC Vet Res       Date:  2012-07-02       Impact factor: 2.741

9.  Letrozole and norethisterone acetate versus letrozole and triptorelin in the treatment of endometriosis related pain symptoms: a randomized controlled trial.

Authors:  Simone Ferrero; Pier L Venturini; David J Gillott; Valentino Remorgida
Journal:  Reprod Biol Endocrinol       Date:  2011-06-21       Impact factor: 5.211

10.  Clarifying the role of three-dimensional transvaginal sonography in reproductive medicine: an evidenced-based appraisal.

Authors:  Nick Raine-Fenning; Arthur C Fleischer
Journal:  J Exp Clin Assist Reprod       Date:  2005-08-11