Literature DB >> 30877406

Multiview Contouring for Breast Tumor on Magnetic Resonance Imaging.

Dar-Ren Chen1, Yao-Wen Chang2, Hwa-Koon Wu3, Wei-Chung Shia1, Yu-Len Huang4.   

Abstract

The shape and contour of the lesion are shown to be effective features for physicians to identify breast tumor as benign or malignant. The region of the lesion is usually manually created by the physician according to their clinical experience; therefore, contouring tumors on breast magnetic resonance imaging (MRI) is difficult and time-consuming. For this purpose, an automatic contouring method for breast tumors was developed for less burden in the analysis and to decrease the observed bias to help in making decisions clinically. In this study, a multiview segmentation method for detecting and contouring breast tumors in MRI was represented. The preprocessing of the proposed method reduces any amount of noises but preserves the shape and contrast of the breast tumor. The two-dimensional (2D) level-set segmentation method extracts contours of breast tumors from the transverse, coronal, and sagittal planes. The obtained contours are further utilized to generate appropriate three-dimensional (3D) contours. Twenty breast tumor cases were evaluated and the simulation results show that the proposed contouring method was an efficient method for delineating 3D contours of breast tumors in MRI.

Entities:  

Keywords:  Breast cancer; Image segmentation; Level-set method; MRI; Multiview contouring

Year:  2019        PMID: 30877406      PMCID: PMC6737172          DOI: 10.1007/s10278-019-00190-7

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  18 in total

1.  The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting.

Authors:  N J Raine-Fenning; J S Clewes; N R Kendall; A K Bunkheila; B K Campbell; I R Johnson
Journal:  Ultrasound Obstet Gynecol       Date:  2003-03       Impact factor: 7.299

2.  Probabilistic segmentation of white matter lesions in MR imaging.

Authors:  Petronella Anbeek; Koen L Vincken; Matthias J P van Osch; Robertus H C Bisschops; Jeroen van der Grond
Journal:  Neuroimage       Date:  2004-03       Impact factor: 6.556

3.  Distance regularized level set evolution and its application to image segmentation.

Authors:  Chunming Li; Chenyang Xu; Changfeng Gui; Martin D Fox
Journal:  IEEE Trans Image Process       Date:  2010-08-26       Impact factor: 10.856

4.  Level set contouring for breast tumor in sonography.

Authors:  Yu-Len Huang; Yu-Ru Jiang; Dar-Ren Chen; Woo Kyung Moon
Journal:  J Digit Imaging       Date:  2007-09       Impact factor: 4.056

Review 5.  The current status of breast MR imaging. Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice.

Authors:  Christiane Kuhl
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

6.  Active contours without edges.

Authors:  T F Chan; L A Vese
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

7.  Diagnostic breast MR imaging: current status and future directions.

Authors:  Elizabeth A Morris
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-02       Impact factor: 2.266

8.  Reproducibility of transvaginal three-dimensional endometrial volume measurements with virtual organ computer-aided analysis (VOCAL) during ovarian stimulation.

Authors:  A Bordes; A M Bory; M Benchaïb; R C Rudigoz; B Salle
Journal:  Ultrasound Obstet Gynecol       Date:  2002-01       Impact factor: 7.299

9.  3-D snake for US in margin evaluation for malignant breast tumor excision using Mammotome.

Authors:  Ruey-Feng Chang; Wen-Jie Wu; Chih-Chi Tseng; Dar-Ren Chen; Woo Kyung Moon
Journal:  IEEE Trans Inf Technol Biomed       Date:  2003-09

10.  Minimization of region-scalable fitting energy for image segmentation.

Authors:  Chunming Li; Chiu-Yen Kao; John C Gore; Zhaohua Ding
Journal:  IEEE Trans Image Process       Date:  2008-10       Impact factor: 10.856

View more
  1 in total

1.  A Noise-robust and Overshoot-free Alternative to Unsharp Masking for Enhancing the Acuity of MR Images.

Authors:  Damodar Reddy Edla; V R Simi; Justin Joseph
Journal:  J Digit Imaging       Date:  2022-03-16       Impact factor: 4.903

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.