Literature DB >> 29225731

Blind Source Separation - Based Motion Detector for Sub-Micrometer, Periodic Displacement in Ultrasonic Imaging.

Md Murad Hossain1, Diwash Thapa2, Justin Sierchio2, Amy Oldenburg2, Caterina Gallippil1.   

Abstract

Sub-micrometer, periodic motion detection using blind source separation (BSS) via principal component analysis (PCA) is presented in the context of magnetomotive ultrasound (MMUS) imaging and Shearwave Dispersion Ultrasound Vibrometry (SDUV). In MMUS, an oscillating external magnetic field displaces tissue loaded with superparamagnetic iron oxide (SPIO) particles, whereas in SDUV, periodic tissue motion is induced using acoustic radiation force (ARF) to measure visco-elastic properties. BSS motion detection performance in MMUS imaging and SDUV was compared against frequency-phase locked (FPL) and normalized cross-correlation (NCC) motion detectors, respectively, in silico and in experimental phantoms. Parametric MMUS phantom images constructed using the BSS method had nearly twice the SNR of the corresponding images constructed using FPL method when a 0.043 mm or smaller kernel size was used. In FEM models of SDUV, the error in the BSS-estimated viscoelastic properties of simulated materials was < 10%, whereas the error was > 20% using NCC when the simulated SNR was 15 dB. In a calibrated elasticity phantom, the amplitude of the motion was ≤ 0.5 μm for a scanner power level ≤ 20%. The median percent error in BSS-derived shear modulus of the phantom was -6.8%, -1.55%, -17.11% for power level of 20%, 15%, and 10%, respectively. The corresponding NCC-derived errors were 29.90%, 127.1%, and 244.70%. These results suggest the relevance of using BSS for the detection of sub-micrometer, periodic motion in MMUS and SDUV imaging, particularly when SNR is less than 15 dB and/or induced displacements are less than 0.5 μm.

Entities:  

Keywords:  Blind Source Separation (BSS); MMUS Imaging; Motion Detection; SDUV

Year:  2016        PMID: 29225731      PMCID: PMC5720174          DOI: 10.1109/ULTSYM.2016.7728880

Source DB:  PubMed          Journal:  IEEE Int Ultrason Symp        ISSN: 1948-5719


  16 in total

1.  Adaptive clutter filtering via blind source separation for two-dimensional ultrasonic blood velocity measurement.

Authors:  Caterina M Gallippi; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2002-10       Impact factor: 1.578

2.  Quantifying elasticity and viscosity from measurement of shear wave speed dispersion.

Authors:  Shigao Chen; Mostafa Fatemi; James F Greenleaf
Journal:  J Acoust Soc Am       Date:  2004-06       Impact factor: 1.840

3.  Independent component analysis: an introduction.

Authors:  James V Stone
Journal:  Trends Cogn Sci       Date:  2002-02-01       Impact factor: 20.229

4.  A finite-element method model of soft tissue response to impulsive acoustic radiation force.

Authors:  Mark L Palmeri; Amy C Sharma; Richard R Bouchard; Roger W Nightingale; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-10       Impact factor: 2.725

5.  Rapid tracking of small displacements with ultrasound.

Authors:  Gianmarco F Pinton; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

6.  Detection of tissue harmonic motion induced by ultrasonic radiation force using pulse-echo ultrasound and Kalman filter.

Authors:  Yi Zheng; Shigao Chen; Wei Tan; Randall Kinnick; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-02       Impact factor: 2.725

7.  Robust principal component analysis and clustering methods for automated classification of tissue response to ARFI excitation.

Authors:  F William Mauldin; Hongtu T Zhu; Russell H Behler; Timothy C Nichols; Caterina M Gallippi
Journal:  Ultrasound Med Biol       Date:  2007-10-29       Impact factor: 2.998

8.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

9.  Single tracking location methods suppress speckle noise in shear wave velocity estimation.

Authors:  Etana C Elegbe; Stephen A McAleavey
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

10.  Shearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity.

Authors:  Shigao Chen; Matthew W Urban; Cristina Pislaru; Randall Kinnick; Yi Zheng; Aiping Yao; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

View more
  2 in total

1.  Effect of Model Thrombus Volume and Elastic Modulus on Magnetomotive Ultrasound Signal Under Pulsatile Flow.

Authors:  Benjamin E Levy; Md Murad Hossain; Justin M Sierchio; Diwash Thapa; Caterina M Gallippi; Amy L Oldenburg
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05-28       Impact factor: 2.725

2.  Blind Source Separation-Based Motion Detector for Imaging Super-Paramagnetic Iron Oxide (SPIO) Particles in Magnetomotive Ultrasound Imaging.

Authors:  Md Murad Hossain; Benjamin E Levy; Diwash Thapa; Amy L Oldenburg; Caterina M Gallippi
Journal:  IEEE Trans Med Imaging       Date:  2018-06-15       Impact factor: 10.048

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.