Literature DB >> 12656378

Characterization of an optical multilayer hydrophone with constant frequency response in the range from 1 to 75 MHz.

Volker Wilkens1.   

Abstract

The performance of an optical multilayer hydrophone for ultrasound measurements is investigated both in theoretical terms and experimentally. The optical measurement system comprises a thin high-finesse dielectric interference filter structure that is deposited onto a plane glass plate. An incident acoustic pressure wave deforms the layer system, and the induced variation of the optical reflectance is determined. Applying the concept of an optical off-axis detection scheme offers good sensitivity and a simple and low-cost setup. A primary interferometric calibration technique is applied to experimentally determine the pressure-voltage transfer function in the range from 1 to 75 MHz. Within the measurement uncertainty a constant transfer factor is obtained for the whole frequency range. Measurements of broadband ultrasound pulses are influenced neither by acoustic resonances of the very thin sensing element nor by diffraction phenomena that are known to cause waveform distortions in small probe hydrophone measurements. High temporal and spatial resolution is combined with high durability of the probe, which is why the optical multilayer hydrophone is well suited for use as a reference for secondary hydrophone calibration.

Year:  2003        PMID: 12656378     DOI: 10.1121/1.1553457

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  7 in total

1.  Broadband optical ultrasound sensor with a unique open-cavity structure.

Authors:  Colin M Chow; Yun Zhou; Yunbo Guo; Theodore B Norris; Xueding Wang; Cheri X Deng; Jing Yong Ye
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  High-resolution ultrasonic imaging using an etalon detector array.

Authors:  Sheng-Wen Huang; Yang Hou; Shai Ashkenazi; Matthew O'Donnell
Journal:  Appl Phys Lett       Date:  2008-09-15       Impact factor: 3.791

4.  Nonlinear Acoustics in Ultrasound Metrology and other Selected Applications.

Authors:  Peter A Lewin
Journal:  Phys Procedia       Date:  2010-01-01

5.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

6.  Low-noise wideband ultrasound detection using polymer microring resonators.

Authors:  Sheng-Wen Huang; Sung-Liang Chen; Tao Ling; Adam Maxwell; Matthew O'Donnell; L Jay Guo; Shai Ashkenazi
Journal:  Appl Phys Lett       Date:  2008-05-15       Impact factor: 3.791

7.  Thin polymer etalon arrays for high-resolution photoacoustic imaging.

Authors:  Yang Hou; Sheng-Wen Huang; Shai Ashkenazi; Russell Witte; Matthew O'Donnell
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

  7 in total