Literature DB >> 12649646

Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference.

Tony Y Kuo1, John G Skedros, Roy D Bloebaum.   

Abstract

RATIONALE AND
OBJECTIVES: The ability of biplane radiography and standard computed tomography (CT) imaging techniques to measure accurately the human femoral anteversion was evaluated and compared with an anatomic reference: the osteometric method.
METHODS: Femoral anteversion of 10 normal adult cadaveric human femora were determined using a standardized anatomic measurement method (the anatomic reference) and the 2 selected common imaging techniques (biplane radiography and CT).
RESULTS: On average, anteversion measurements using biplane radiography were 21/2 times greater in magnitude than measurements using the anatomic reference (absolute mean difference, 13.5 degrees; P = 0.004). In contrast, the discrepancy between CT and anatomic reference measurements was notably less and not statistically significant (absolute mean difference, 2.8 degrees; P = 0.351). In addition, biplane radiography demonstrated greater inter- and intrarater variability than CT imaging for repeated measurements of the same bone specimens.
CONCLUSIONS: Compared with the anatomic reference, CT imaging was an accurate and valid technique for measuring the femoral anteversion. In contrast, biplane radiography demonstrated significant inconsistencies in the measurement of this anatomic parameter.

Entities:  

Mesh:

Year:  2003        PMID: 12649646     DOI: 10.1097/01.RLI.0000059542.90854.EF

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  21 in total

1.  Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography.

Authors:  M Lucius Pomerantz; Diana Glaser; Josh Doan; Sita Kumar; Eric W Edmonds
Journal:  Skeletal Radiol       Date:  2014-10-17       Impact factor: 2.199

2.  3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system.

Authors:  Yeon Soo Lee; Seung Hoon Oh; Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon
Journal:  Med Biol Eng Comput       Date:  2006-09-29       Impact factor: 2.602

3.  Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques.

Authors:  Emmanouil Liodakis; Iosifina Doxastaki; Kongfai Chu; Christian Krettek; Ralph Gaulke; Musa Citak; Mohamed Kenawey
Journal:  Skeletal Radiol       Date:  2011-05-11       Impact factor: 2.199

4.  Femoral and tibial torsion measurements in children and adolescents: comparison of MRI and 3D models based on low-dose biplanar radiographs.

Authors:  Andrea B Rosskopf; Florian M Buck; Christian W A Pfirrmann; Leonhard E Ramseier
Journal:  Skeletal Radiol       Date:  2017-02-03       Impact factor: 2.199

5.  Structure, sex, and strength and knee and hip kinematics during landing.

Authors:  Jennifer S Howard; Melisa A Fazio; Carl G Mattacola; Timothy L Uhl; Cale A Jacobs
Journal:  J Athl Train       Date:  2011 Jul-Aug       Impact factor: 2.860

6.  Quantitative assessment of changes in lesser trochanter shapes in relation to femoral rotations.

Authors:  Ali Turgut; Anıl Koca; Melikşah Uzakgider; Sertan Hancıoğlu; Serkan Erkuş; Önder Kalenderer
Journal:  Acta Orthop Traumatol Turc       Date:  2020-03       Impact factor: 1.511

7.  MPR realignment increases accuracy when measuring femoral neck anteversion angle.

Authors:  Tommy Hemmert Olesen; Trine Torfing; Søren Overgaard
Journal:  Skeletal Radiol       Date:  2013-05-21       Impact factor: 2.199

8.  Does MIPO of fractures of the distal femur result in more rotational malalignment than ORIF? A retrospective study.

Authors:  M Lill; R Attal; A Rudisch; M C Wick; M Blauth; M Lutz
Journal:  Eur J Trauma Emerg Surg       Date:  2015-11-10       Impact factor: 3.693

9.  Accuracy of the relationship between the centre of the femoral head and tip of greater trochanter.

Authors:  Baljinder S Dhinsa; Aaron Saini; Alastair G Dick; William J Nash; Obinna Nzeako; Zameer Shah
Journal:  J Clin Orthop Trauma       Date:  2018-08-24

10.  The rotational fixator: A new device.

Authors:  T Omar Pacha; A Khalifa; T Graulich; H Alaidarous; M Omar; C Krettek; T Stubig
Journal:  J Orthop       Date:  2019-12-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.