Literature DB >> 12648929

Simultaneous or scanning data acquisition? A theoretical comparison relevant to inductively coupled plasma sector-field mass spectrometers.

David A Solyom1, Gary M Hieftje.   

Abstract

The benefits of simultaneous multichannel detection over single-channel scanning detection are well established in analytical chemistry. Multichannel detection increases duty cycle, which leads to enhanced sensitivity, detection limits, and reduced analysis time. Also, multichannel detection used with either isotope-ratio or internal-standard techniques provides a mechanism to reduce the effect of multiplicative or flicker noise prevalent in plasma sources. An additional benefit of simultaneous detection is superior analysis of short-lived transient signals. Presented here is a theoretical comparison between simultaneous/continuous multichannel acquisition and single-channel scanning acquisition. To conduct this comparison, reported sensitivity, single-channel precision, and background values for commercial inductively coupled plasma sector-field mass spectrometers (ICP-SFMS) are used to generate theoretical figures of merit for both acquisition methods. Among the figures of merit that will be considered are detection limits, precision, and analysis time, particularly for multi-element or multi-isotope analysis.

Year:  2003        PMID: 12648929     DOI: 10.1016/S1044-0305(02)00910-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  5 in total

1.  Comparative performance study of ICP mass spectrometers by means of U "isotopic measurements".

Authors:  C R Quétel; J Vogl; T Prohaska; S Nelms; P D Taylor; P De Bièvre
Journal:  Fresenius J Anal Chem       Date:  2000 Sep-Oct

2.  Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughput.

Authors:  M K Bayliss; D Little; D N Mallett; R S Plumb
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

3.  Novel multichannel plasma-source mass spectrometer.

Authors:  E F Cromwell; P Arrowsmith
Journal:  J Am Soc Mass Spectrom       Date:  1996-05       Impact factor: 3.109

4.  Fourier transform spectroscopic imaging using an infrared focal-plane array detector.

Authors:  E N Lewis; P J Treado; R C Reeder; G M Story; A E Dowrey; C Marcott; I W Levin
Journal:  Anal Chem       Date:  1995-10-01       Impact factor: 6.986

5.  Product Review: ICPMS--Beyond quadrupole.

Authors:  B E Erickson
Journal:  Anal Chem       Date:  1999-12-01       Impact factor: 6.986

  5 in total
  2 in total

1.  Distance-of-Flight Mass Spectrometry with IonCCD Detection and an Inductively Coupled Plasma Source.

Authors:  Elise A Dennis; Steven J Ray; Christie G Enke; Alexander W Gundlach-Graham; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2015-11-09       Impact factor: 3.109

2.  A new microfluidics-based droplet dispenser for ICPMS.

Authors:  Pascal E Verboket; Olga Borovinskaya; Nicole Meyer; Detlef Günther; Petra S Dittrich
Journal:  Anal Chem       Date:  2014-05-31       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.