Literature DB >> 11085416

Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughput.

M K Bayliss1, D Little, D N Mallett, R S Plumb.   

Abstract

Recent years have seen increasing usage of large particle size stationary phases and ultra-high flow rate liquid chromatography/mass spectrometry (LC/MS) for rapid determination of pharmaceuticals in plasma without prior sample preparation. This lack of sample preparation prior to analysis, together with the extremely high throughput of the chromatography, makes the technique extremely attractive to the bioanalyst. Further, the introduction of multiple sprayer interfaces to mass spectrometers provides the potential for even higher throughput. In this paper, we present parallel ultra-high flow rate liquid chromatography using four columns in parallel and a four-way multiple sprayer interface to the mass spectrometer. We have applied this on both the narrow-bore and capillary scale. This technique enables the quantification of drugs from four plasma samples simultaneously, at nanogram per millilitre concentrations, from small aliquots of plasma without sample preparation and with throughputs of up to 120 samples per hour.

Mesh:

Substances:

Year:  2000        PMID: 11085416     DOI: 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO;2-2

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Application of parallel liquid chromatography/mass spectrometry for high throughput microsomal stability screening of compound libraries.

Authors:  Rongda Xu; Csaba Nemes; Kelly M Jenkins; Robyn A Rourick; Daniel B Kassel; Charles Z C Liu
Journal:  J Am Soc Mass Spectrom       Date:  2002-02       Impact factor: 3.109

2.  Temperature-modulated array high-performance liquid chromatography.

Authors:  A Premstaller; W Xiao; H Oberacher; M O'Keefe; D Stern; T Willis; C G Huber; P J Oefner
Journal:  Genome Res       Date:  2001-11       Impact factor: 9.043

3.  Simultaneous or scanning data acquisition? A theoretical comparison relevant to inductively coupled plasma sector-field mass spectrometers.

Authors:  David A Solyom; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2003-03       Impact factor: 3.109

4.  Fully automated four-column capillary LC-MS system for maximizing throughput in proteomic analyses.

Authors:  Eric A Livesay; Keqi Tang; Beverley K Taylor; Michael A Buschbach; Derek F Hopkins; Brian L LaMarche; Rui Zhao; Yufeng Shen; Daniel J Orton; Ronald J Moore; Ryan T Kelly; Harold R Udseth; Richard D Smith
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.