Comparative performance study of ICP mass spectrometers by means of U "isotopic measurements".

C R Quétel1, J Vogl, T Prohaska, S Nelms, P D Taylor, P De Bièvre.   

Abstract

The performance of four commercially available ICPMS instruments of three different types was compared by means of uranium "isotopic measurements". Examined were two quadrupole sector (different generation, different manufacturer), one single detector double focusing magnetic sector and one multiple collector double focusing magnetic sector instruments. The same samples of the IRMM-072 series were used under routine conditions to measure the 233U/235U and the 233U/238U ratios which, in these samples, vary over almost three orders of magnitude from approximately 1 to approximately 2 x 10(-3). Within expanded (k = 2) uncertainties, good agreement was observed between the certified values and the data internally corrected for mass-discrimination effects. The magnitude of the evaluated uncertainties was different for each type of instrument. With the multiple collector instrument, expanded uncertainties varied from +/- 0.04% to +/- 0.24% for the 233U/235U ratio, and from +/- 0.08% to +/- 0.27% for the 233U/238U ratio. They were approximately 1 to 5 times larger with the single detector magnetic sector instrument, and approximately 10 to 25 times larger with both quadrupole sector instruments. With the multiple collector instrument, repeatability of the measurements seemed to be limited by the difficulty of correcting properly for instrumental background, whereas with the single detector magnetic sector instrument the counting statistics was the only limitation (on smallest ratios). Apparent mass-discrimination was clearly found to be larger but more reproducible (and hence easier to correct for) in the case of magnetic sector instruments than for both quadrupole sector instruments. If space charge effects were the main source of mass-discrimination for all instruments, these results are in contradiction with the hypothesis of the size of mass-discrimination decreasing with the acceleration voltage. With the single detector magnetic sector instrument in particular (when operated by changing the ion energy only), our results pointed at more than only one major source of mass-discrimination, with variable size depending on the ratios measured.

Year:  2000        PMID: 11220572     DOI: 10.1007/s002160000499

Source DB:  PubMed          Journal:  Fresenius J Anal Chem        ISSN: 0937-0633


  4 in total

1.  Simultaneous or scanning data acquisition? A theoretical comparison relevant to inductively coupled plasma sector-field mass spectrometers.

Authors:  David A Solyom; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2003-03       Impact factor: 3.109

2.  Low uncertainty reverse isotope dilution ICP-MS applied to certifying an isotopically enriched Cd candidate reference material: a case study.

Authors:  Ivan Tresl; Christophe R Quétel
Journal:  J Am Soc Mass Spectrom       Date:  2005-05       Impact factor: 3.109

3.  Mass discrimination during MC-ICPMS isotopic ratio measurements: investigation by means of synthetic isotopic mixtures (IRMM-007 series) and application to the calibration of natural-like zinc materials (including IRMM-3702 and IRMM-651).

Authors:  Emmanuel Ponzevera; Christophe R Quétel; Michael Berglund; Philip D P Taylor; Peter Evans; Robert D Loss; Giuseppino Fortunato
Journal:  J Am Soc Mass Spectrom       Date:  2006-07-28       Impact factor: 3.109

4.  The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

Authors:  Ondrej Hanousek; Marion Brunner; Daniel Pröfrock; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Methods       Date:  2016-09-23       Impact factor: 2.896