Literature DB >> 7981519

Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography.

Y P Du1, D L Parker, W L Davis, G Cao.   

Abstract

Partial-volume artifacts reduce vessel contrast and continuity (especially in small vessels) in magnetic resonance (MR) angiography. The authors applied zero-filled (band-limited) interpolation to three-dimensional (3D) MR angiograms to reduce partial-volume artifacts. They demonstrated that zero-filled interpolation can also be implemented by means of voxel shifting in real space. Voxel-shifted interpolation is much less computer memory intensive than conventional zero-filled interpolation. They numerically simulated the contrast loss due to partial-volume artifacts and contrast recovery obtained with zero-filled interpolation. Zero-filled interpolation in all three orthogonal directions was applied to 3D MR angiography data sets from 29 human studies. These studies were obtained with the three commonly used 3D MR angiography techniques: 3D time of flight, multislab 3D time of flight, and 3D phase contrast. A substantial improvement in vessel contrast and vessel continuity was observed in all cases.

Entities:  

Mesh:

Year:  1994        PMID: 7981519     DOI: 10.1002/jmri.1880040517

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  47 in total

1.  3D contrast-enhanced MR angiography using fluoroscopic triggering and an elliptical centric view order.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  Int J Card Imaging       Date:  1999-04

2.  Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

3.  A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography.

Authors:  Y P Du; E R McVeigh; D A Bluemke; H A Silber; T K Foo
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

Review 4.  [Magnetic resonance imaging. Sequence acronyms and other abbreviations in MR imaging].

Authors:  W R Nitz
Journal:  Radiologe       Date:  2003-09       Impact factor: 0.635

Review 5.  Quantitative evaluation of carotid atherosclerotic plaques by magnetic resonance imaging.

Authors:  Chun Yuan; Xue-Qiao Zhao; Thomas S Hatsukami
Journal:  Curr Atheroscler Rep       Date:  2002-09       Impact factor: 5.113

6.  Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination.

Authors:  Stephan G Wetzel; Glyn Johnson; Andrew G S Tan; Soonmee Cha; Edmond A Knopp; Vivian S Lee; David Thomasson; Neil M Rofsky
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

7.  High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Tatsuya Nakamura; Hiroshi Fukatsu; Takeo Ishigaki; Ikuo Aoki
Journal:  Eur Radiol       Date:  2003-05-07       Impact factor: 5.315

8.  Image interpolation improves the zonal analysis of cartilage T2 relaxation in MRI.

Authors:  Farid Badar; Yang Xia
Journal:  Quant Imaging Med Surg       Date:  2017-04

9.  Improved MR thermometry for laser interstitial thermotherapy.

Authors:  Henrik Odéen; Dennis L Parker
Journal:  Lasers Surg Med       Date:  2019-01-15       Impact factor: 4.025

10.  3D multi-parametric breast MRI segmentation using hierarchical support vector machine with coil sensitivity correction.

Authors:  Yi Wang; Glen Morrell; Marta E Heibrun; Allison Payne; Dennis L Parker
Journal:  Acad Radiol       Date:  2012-10-23       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.