Measurement of image contrast using diffraction enhanced imaging.

Miklos Z Kiss1, Dale E Sayers, Zhong Zhong.   

Abstract

Refraction contrast of simple objects obtained using diffraction enhanced imaging (DEI) was studied and compared to conventional radiographic contrast. Lucite cylinders and nylon wires were imaged using monochromatic synchrotron radiation at the National Synchrotron Light Source (http://nslsweb. nsls.bnl.gov/nsls/Default.htm) at the Brookhaven National Laboratory. The DEI images were obtained by placing a silicon analyser crystal tuned to the [333] diffraction plane in the beam path between the sample and the detector. To compare the DEI images with conventional radiographic images requires a consistent definition of refraction and absorption contrast. Conventional definitions of contrast favour conventional radiography and DEI contrast is defined to emphasize the specific characteristics of DEI. The proposed definitions were then used to find the DEI gain (the ratio of the DEI contrast with respect to the conventional image contrast). The results presented here show that the DEI gain is consistently greater than 1, indicating that DEI provides more contrast information than conventional radiography.

Mesh:

Year:  2003        PMID: 12608610     DOI: 10.1088/0031-9155/48/3/304

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Noise properties and task-based evaluation of diffraction-enhanced imaging.

Authors:  Jovan G Brankov; Alejandro Saiz-Herranz; Miles N Wernick
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-11

2.  Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study.

Authors:  Di Wu; Molly Donovan Wong; Yuhua Li; Laurie Fajardo; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2017-11-21       Impact factor: 3.609

3.  Using Microbubble as Contrast Agent for High-Energy X-Ray In-line Phase Contrast Imaging: Demonstration and Comparison Study.

Authors:  Di Wu; Molly Donovan Wong; Kai Yang; Aimin Yan; Yuhua Li; Laurie Fajardo; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-21       Impact factor: 4.538

4.  Phase-sensitive X-ray imaging of synovial joints.

Authors:  J Li; Z Zhong; D Connor; J Mollenhauer; C Muehleman
Journal:  Osteoarthritis Cartilage       Date:  2009-03-24       Impact factor: 6.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.