Literature DB >> 12601200

Suspected pulmonary embolism: enhancement of pulmonary arteries at deep-inspiration CT angiography--influence of patent foramen ovale and atrial-septal defect.

Christine B Henk1, Stephan Grampp, Kenneth F Linnau, Majda M Thurnher, Christian Czerny, Christian J Herold, Gerhard H Mostbeck.   

Abstract

PURPOSE: To investigate if abnormal early contrast enhancement of the aorta and decreased attenuation of pulmonary arteries at deep-inspiration spiral computed tomographic (CT) angiography might be caused by a patent foramen ovale (PFO).
MATERIALS AND METHODS: Two hundred forty-four spiral CT angiographic images of the pulmonary arteries obtained during deep inspiration in patients suspected of having pulmonary embolism (PE) were reviewed for evidence of abnormal early enhancement of the aorta. In 45 patients, enhancement of the ascending aorta was equal to or more than that of the pulmonary arteries. Nonenhanced or contrast material-enhanced echocardiography was performed in 39 of these cases. All CT images with abnormal enhancement patterns were graded for contrast quality with respect to sufficient enhancement of pulmonary arteries (four grades) at three anatomic levels: right and left main and lobar and segmental branches. In addition, all spiral CT angiographic images were evaluated concerning the diagnosis of PE and the grouping of central (main pulmonary artery to proximal lobar arteries) and peripheral (beyond proximal lobar branches) locations of emboli. Mean attenuation values of ascending aortas and main pulmonary arteries in group 1 (n = 244) were compared with those in groups 2 and 3 (n = 45) by means of the two-tailed Student t test for unpaired data (P <.05).
RESULTS: Attenuation values for ascending aortas in group 1 were significantly lower than those in groups 2 and 3 (P <.001). Attenuation values in main pulmonary arteries were significantly higher in group 1 than in groups 2 and 3 (P <.001). Echocardiographic images showed an intracardiac right-to-left shunt in all 39 cases with abnormal contrast dynamics in the CT study (16% of the whole study population). Three patients had an atrial-septal defect, and 36 had a PFO. Images with a shunt had good (9%), intermediate (37%), fair (33%), and poor (23%) contrast of the pulmonary arteries. Sufficient vessel contrast for the diagnosis of PE could not be achieved in 27 of 45 patients with a shunt, but severe central PE could be ruled out. PE could be diagnosed in 31% of the 244 images, 58% were negative, and 11% were indeterminate.
CONCLUSION: A PFO may frequently lead to insufficient attenuation of the pulmonary arteries, which potentially limits the diagnosis of PE if the examination is performed during deep inspiration.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12601200     DOI: 10.1148/radiol.2263012200

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  MDCT for suspected pulmonary embolism: multi-institutional survey of 16-MDCT data acquisition protocols.

Authors:  Pamela T Johnson; David Naidich; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2006-11-29

Review 2.  We Built This House; It's Time to Move in: Leveraging Existing DICOM Structure to More Completely Utilize Readily Available Detailed Contrast Administration Information.

Authors:  Jeffrey D Hirsch; Eliot L Siegel; Sridhar Balasubramanian; Kenneth C Wang
Journal:  J Digit Imaging       Date:  2015-08       Impact factor: 4.056

Review 3.  Haemodynamic findings on cardiac CT in children with congenital heart disease.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2010-12-03

4.  Determination of lowest possible contrast volume in computed tomography pulmonary angiography by using pulmonary transit time.

Authors:  Koray Kilic; Gonca Erbas; Murat Ucar; Koray Akkan; Nil Tokgoz; Mehmet Arac; Sedat Isik
Journal:  Jpn J Radiol       Date:  2014-01-05       Impact factor: 2.374

5.  Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality.

Authors:  J C L Rodrigues; D Joshi; S M Lyen; I S Negus; N E Manghat; M C K Hamilton
Journal:  Eur Radiol       Date:  2014-06-26       Impact factor: 5.315

6.  Does pregnancy affect vascular enhancement in patients undergoing CT pulmonary angiography?

Authors:  Adrian K Andreou; John J Curtin; Sue Wilde; Allan Clark
Journal:  Eur Radiol       Date:  2008-07-24       Impact factor: 5.315

7.  Quality of CT pulmonary angiography for suspected pulmonary embolus in pregnancy.

Authors:  Jean Marie U-King-Im; Susan J Freeman; Teresa Boylan; Heok K Cheow
Journal:  Eur Radiol       Date:  2008-07-24       Impact factor: 5.315

8.  Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography.

Authors:  Tommaso D'Angelo; Andreas M Bucher; Lukas Lenga; Christophe T Arendt; Julia L Peterke; Damiano Caruso; Silvio Mazziotti; Alfredo Blandino; Giorgio Ascenti; Ahmed E Othman; Simon S Martin; Doris Leithner; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2017-10-10       Impact factor: 5.315

9.  Waiting to exhale: salvaging the nondiagnostic CT pulmonary angiogram by using expiratory imaging to improve contrast dynamics.

Authors:  Yung Hsin Chen; Vinodkumar Velayudhan; David I Weltman; Dvorah Balsam; Nick Patel; Kathryn A Draves; Kathryn A Robinson; Thinh H Vu
Journal:  Emerg Radiol       Date:  2008-01-10

10.  Enhancement of the pulmonary arteries and thoracic aorta: comparison of a biphasic contrast injection and fixed delay protocol with a monophasic injection and a timing bolus protocol.

Authors:  Anda M Cornea; Brendan J McCullough; Lee M Mitsumori; Martin L D Gunn
Journal:  Emerg Radiol       Date:  2014-09-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.