Literature DB >> 12601031

Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure.

Jianhua Wang1, Desmond Fonn, Trefford L Simpson.   

Abstract

PURPOSE: To determine changes in topographical thickness of the epithelium and total cornea after hydrogel (2-hydroxyethyl methacrylate; HEMA or soft lens) and PMMA rigid contact lens wear with eyes closed, as measured by optical coherence tomography (OCT).
METHODS: Epithelial and total corneal thickness in 18 neophyte eyes was measured with OCT at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after 3 hours of soft and rigid contact lens wear with the eye closed. These measurements were repeated 20 minutes after removal of the lenses.
RESULTS: Lens type, time, and location were found to be significant main influences (P < 0.0001) on corneal swelling in patched eyes, by three-way ANOVA, and there was a significant three-way interaction among lens type, time, and location (F((16,272)) = 1.78, P = 0.033). However, there was no significant main effect and interaction of epithelial thickness (F((16, 272)) = 0.33, P = 0.99). Immediately after removal of the lenses, total corneal thickness in the horizontal meridian was significantly greater with both soft and PMMA lenses (P < 0.001) at each location with each lens, compared with the baseline measurements. With both lenses, the increase in actual thickness and percentage of corneal swelling at the center was greater than at each peripheral point (excluding the first 10 degrees points; P < 0.005). HEMA lenses caused greater corneal swelling than the PMMA lenses at each location immediately after removal of the lenses (P < 0.005).
CONCLUSIONS: This study shows that corneal swelling is dependent on lens type and corneal location when eyes are closed, but epithelial thickness across the horizontal corneal meridian does not change during lens wear with eyes closed. OCT is an efficient method of measuring topographical corneal and epithelial thickness in response to contact lens wear.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12601031     DOI: 10.1167/iovs.02-0343

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  15 in total

1.  Epithelial thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2008-06       Impact factor: 3.573

2.  Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography.

Authors:  Aizhu Tao; Jianhua Wang; Qi Chen; Meixiao Shen; Fan Lu; Sander R Dubovy; Mohamed Abou Shousha
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-01       Impact factor: 4.799

3.  First demonstration of ocular refractive change using blue-IRIS in live cats.

Authors:  Daniel E Savage; Daniel R Brooks; Margaret DeMagistris; Lisen Xu; Scott MacRae; Jonathan D Ellis; Wayne H Knox; Krystel R Huxlin
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-07-01       Impact factor: 4.799

4.  Assessment of corneal properties based on statistical modeling of OCT speckle.

Authors:  Danilo A Jesus; D Robert Iskander
Journal:  Biomed Opt Express       Date:  2016-12-08       Impact factor: 3.732

5.  Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography.

Authors:  Chixin Du; Jianhua Wang; Lele Cui; Meixiao Shen; Yimin Yuan
Journal:  Cornea       Date:  2012-09       Impact factor: 2.651

6.  Entire thickness profiles of the epithelium and contact lens in vivo imaged with high-speed and high-resolution optical coherence tomography.

Authors:  Aizhu Tao; Yilei Shao; Hong Jiang; Yufeng Ye; Fan Lu; Meixiao Shen; Dexi Zhu; Jianhua Wang
Journal:  Eye Contact Lens       Date:  2013-09       Impact factor: 2.018

7.  Evaluation of rigid gas permeable lens fitting in keratoconic patients with optical coherence tomography.

Authors:  Amal M Elbendary; Waleed Abou Samra
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-08       Impact factor: 3.117

8.  Vertical and horizontal corneal epithelial thickness profile using ultra-high resolution and long scan depth optical coherence tomography.

Authors:  Shuangqing Wu; Aizhu Tao; Hong Jiang; Zhe Xu; Victor Perez; Jianhua Wang
Journal:  PLoS One       Date:  2014-05-20       Impact factor: 3.240

9.  Topical rosiglitazone is an effective anti-scarring agent in the cornea.

Authors:  Krystel R Huxlin; Holly B Hindman; Kye-Im Jeon; Jens Bühren; Scott MacRae; Margaret DeMagistris; David Ciufo; Patricia J Sime; Richard P Phipps
Journal:  PLoS One       Date:  2013-08-05       Impact factor: 3.240

Review 10.  The Safety of Orthokeratology--A Systematic Review.

Authors:  Yue M Liu; Peiying Xie
Journal:  Eye Contact Lens       Date:  2016-01       Impact factor: 2.018

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.