Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis.

Siegfried Peer1, Salvatore M Giacomuzzi, Regina Peer, Eva Gassner, Iris Steingruber, Werner Jaschke.   

Abstract

With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings.

Mesh:

Year:  2002        PMID: 12599009     DOI: 10.1007/s00330-002-1479-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

1.  Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

Authors:  Patrick Mc Laughlin; Siobhan O Neill; Noel Fanning; Anne Marie Mc Garrigle; Owen J O Connor; Gerry Wyse; Michael M Maher
Journal:  Emerg Radiol       Date:  2011-12-16

2.  Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Mireille V Boot; Bart J A Mertens; Jacob Geleijns
Journal:  Eur Radiol       Date:  2005-08-31       Impact factor: 5.315

3.  ROC analysis for diagnostic accuracy of fracture by using different monitors.

Authors:  Zhigang Liang; Kuncheng Li; Xiaolin Yang; Xiangying Du; Jiabin Liu; Xin Zhao; Xiangdong Qi
Journal:  J Digit Imaging       Date:  2006-09       Impact factor: 4.056

4.  Comparison of color LCD and medical-grade monochrome LCD displays in diagnostic radiology.

Authors:  Håkan Geijer; Mats Geijer; Lillemor Forsberg; Susanne Kheddache; Patrik Sund
Journal:  J Digit Imaging       Date:  2007-06       Impact factor: 4.056

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.