Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis.

Fansan Zhu1, Shubho Sarkar, Charoen Kaitwatcharachai, Roger Greenwood, Claudio Ronco, Nathan W Levin.   

Abstract

UNLABELLED: The usefulness of regional bioimpedance analysis (RBIA) in determining the dry weight in dialysis patients is currently being investigated. The aim of this study was to evaluate the reproducibility of measurement of resistivity in the calf.
METHODS: Twenty-five normal subjects and 10 patients undergoing regular hemodialysis were studied. Four electrodes inserted into a blood pressure cuff were placed on the calf. Bioimpedance was continuously measured over 3- to 5-min periods (Xitron Hydra). After a resting period of 1 min, cuff pressure was increased to above the systolic blood pressure (SBP) for a few seconds to expel excess ECF fluid and then deflated. The effect on recordings of moving the electrodes 2 cm higher and then 2 cm lower than the normal position was studied in 8 normal subjects. In a second study of reproducibility, post-dialysis measurements were made twice in 10 patients who maintained the same post-dialysis target weight throughout the study period.
RESULTS: The mean resting resistivity rho(0) in normal subjects was 532.6 +/- 95 omega.cm rising to 583.9 +/- 99.7 omega.cm when cuff pressure was applied rho(p). The average values of rho(0) and rho(p) in patients post-dialysis were 489 +/- 74 and 537 +/- 77 respectively showing that there were no significant differences in rho(0) and rho(p) between normal subjects and patients post-dialysis. The mean values of change in resistivity when the electrodes were shifted between the lowest and highest positions on the calf were -3.66 +/- 4.45 and -1.44 +/- 3.82%, respectively. Repeat measurement of resistivity in patients post-dialysis varied by 2.04 +/- 2.29% while post-dialysis body weight varied by 0.17 +/- 0.47%.
CONCLUSION: In this study, resistivity measurement by RBIA at the calf showed similar levels of fluid loading in patients post-dialysis as in normal subjects. This study also showed that change in electrode position resulted in a mean change in resistivity of <5% and repeated measurements showed a change in resistivity <3% while body weight changes were <0.2%. This technique appears to have an acceptable level of reproducibility for its application to the assessment of patient hydration.

Entities:  

Mesh:

Year:  2003        PMID: 12596759     DOI: 10.1159/000067855

Source DB:  PubMed          Journal:  Blood Purif        ISSN: 0253-5068            Impact factor:   2.614


  6 in total

Review 1.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

2.  Three-dimensional micro-computed tomographic imaging of alveolar bone in experimental bone loss or repair.

Authors:  Chan Ho Park; Zachary R Abramson; Mario Taba; Qiming Jin; Jia Chang; Jaclynn M Kreider; Steven A Goldstein; William V Giannobile
Journal:  J Periodontol       Date:  2007-02       Impact factor: 6.993

3.  A comparison of the thresholding strategies of micro-CT for periodontal bone loss: a pilot study.

Authors:  P-C Chang; K Liang; J C Lim; M-C Chung; L-Y Chien
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

4.  Extracellular fluid management and hypertension in urban dwelling versus rural dwelling hemodialysis patients.

Authors:  Marcello Tonelli; Anita Lloyd; Neesh Pannu; Scott Klarenbach; Pietro Ravani; Kailash Jindal; Jennifer MacRae; Larry Unsworth; Braden Manns; Brenda Hemmelgarn
Journal:  J Nephrol       Date:  2016-08-23       Impact factor: 3.902

5.  Use of lung ultrasonography to determine the accuracy of clinically estimated dry weight in chronic hemodialysis patients.

Authors:  Chuan Jiang; Satyam Patel; Andrew Moses; Maria V DeVita; Michael F Michelis
Journal:  Int Urol Nephrol       Date:  2017-10-03       Impact factor: 2.370

6.  Effectiveness of elevated vacuum and suction prosthetic suspension systems in managing daily residual limb fluid volume change in people with transtibial amputation.

Authors:  Robert T Youngblood; Jacob T Brzostowski; Brian J Hafner; Joseph M Czerniecki; Katheryn J Allyn; Richard L Foster; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2020-03-18       Impact factor: 1.895

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.