Literature DB >> 12585053

[Comparison of mechanical properties of orthodontic nickel-titanium wires].

D Kayser1, C Bourauel, B Braumann, A Jäger.   

Abstract

Two packages each, containing 10 wires per package, of different batches of 25 different types of orthodontic archwires made of super-elastic nickel-titanium alloys measuring 0.41 x 0.56 mm2, were investigated. The wires were characterized by obtaining the following measurements at an ambient temperature of 37 degrees: a three-point bending test with the supporting points spaced 10 mm apart, and determination of the torque/bending angle curves using a pure bending test. The force/deflection curves provided the parameters characterizing the super-elastic unloading plateau: average force, slope and endpoint. From the torque/bending angle curves, the parameters average torque, plateau endpoint and the elasticity parameters were determined. Average force (0.8-4.5 N), endpoint (0.2-0.9 mm) and the slope of the unloading plateau (0.2-2.1 N/mm) of the three-point bending test clearly differed for individual wires. Significant differences were also seen for average torque (1.5-11.5 Nmm), unloading plateau endpoint (2.7-20.0 degrees) and elasticity parameters epsilon 4, E4, E5 and E6 in the pure bending test. Individual batches showed only minor differences. The results permit the conclusion to be drawn that super-elasticity is applicable to only a small portion of the wires examined. Although other wires showed super-elastic behaviour, the unloading plateaus has a force level of up to 6 N, and cannot be recommended for orthodontic application. The super-elastic plateau is often of use only for deflections greater than 1.5 mm. The use of super-elastic archwires made of nickel-titanium alloys makes sense only when the elastic properties of the respective wires are known. This makes the provision by the manufacturer of relevant data on the elastic properties of wires a necessity.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12585053     DOI: 10.1515/bmte.2002.47.12.334

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  4 in total

1.  Experimental analysis of torque characteristics of orthodontic wires.

Authors:  Samira Partowi; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2010-10-21       Impact factor: 1.938

2.  Numerical simulation and biomechanical analysis of an orthodontically treated periodontally damaged dentition.

Authors:  A Kettenbeil; S Reimann; C Reichert; L Keilig; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2013-11-01       Impact factor: 1.938

Review 3.  Which Orthodontic Wire and Working Sequence Should be Preferred for Alignment Phase? A Review.

Authors:  Sedef Sera Hepdarcan; R Burcu Nur Yılmaz; Didem Nalbantgil
Journal:  Turk J Orthod       Date:  2016-06-01

4.  Flexural properties of rectangular nickel-titanium orthodontic wires when used as ribbon archwires.

Authors:  Li Lin; G Fräns Currier; Onur Kadioglu; Fernando L Esteban Florez; David M Thompson; Sharukh S Khajotia
Journal:  Angle Orthod       Date:  2018-08-03       Impact factor: 2.079

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.