Literature DB >> 30080130

Flexural properties of rectangular nickel-titanium orthodontic wires when used as ribbon archwires.

Li Lin, G Fräns Currier, Onur Kadioglu, Fernando L Esteban Florez, David M Thompson, Sharukh S Khajotia.   

Abstract

OBJECTIVE: To compare the flexural properties of rectangular nickel-titanium (Ni-Ti) orthodontic wires in occlusoapical and faciolingual orientations using a standardized test method.
MATERIALS AND METHODS: Twenty-two rectangular Ni-Ti wire groups were tested in occlusoapical (ribbon) orientation: eight conventional Ni-Ti products, five superelastic Ni-Ti products, and nine thermal Ni-Ti products (n = 10 per group). Six products of thermal Ni-Ti wire were tested in faciolingual (edgewise) orientation. A three-point bending test was performed to measure deactivation force at 3.0-, 2.0-, 1.0-, and 0.5-mm deflections of each rectangular wire at 37.0 ± 0.5°C. Analysis of variance and post hoc Student-Newman-Keuls tests were used to compare the mean values of the different groups (α = .05).
RESULTS: The ranges of deactivation forces varied greatly with different kinds, sizes, products, and deflections of Ni-Ti wires. One product of conventional and superelastic Ni-Ti wires had steeper force-deflection curves. Four products had similarly shaped flat force-deflection curves, whereas the sixth product had a moderately steep force-deflection curve. Thermal Ni-Ti wires had smaller deactivation forces ranging from 0.773 N (78.8 g) to 2.475 N (252.4 g) between deflections of 1.0 and 0.5 mm, whereas wider ranges of force from 3.371 N (343.7 g) to 9.343 N (952.7 g) were predominantly found among conventional Ni-Ti wires between deflections of 3.0 and 2.0 mm.
CONCLUSIONS: Clinicians should critically select archwires for use in the occlusoapical orientation not only based on Ni-Ti wire type, size (0.022 × 0.016-in or 0.025 × 0.017-in), and product but also with deactivation deflections from 0.5 and 1.0 mm to obtain light forces in the occlusoapical orientation.

Entities:  

Keywords:  Conventional Ni-Ti; Copper Ni-Ti; Edgewise archwires; Ribbon archwires; Superelastic Ni-Ti; Thermal Ni-Ti

Mesh:

Substances:

Year:  2018        PMID: 30080130      PMCID: PMC8137118          DOI: 10.2319/021717-118.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  17 in total

1.  The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending.

Authors:  T R Meling; J Odegaard
Journal:  Am J Orthod Dentofacial Orthop       Date:  2001-03       Impact factor: 2.650

2.  Load-deflection characteristics of superelastic nickel-titanium orthodontic wires.

Authors:  Peter D Wilkinson; Peter S Dysart; James A A Hood; G Peter Herbison
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-05       Impact factor: 2.650

3.  Fabrication of lingual orthodontic appliances: past, present and future.

Authors:  Ian Hutchinson; Jang Yeol Lee
Journal:  J Orthod       Date:  2013-09

4.  Superelastic materials displaying different force levels within one archwire.

Authors:  D M Ibe; D Segner
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

Review 5.  A review of contemporary archwires: their properties and characteristics.

Authors:  R P Kusy
Journal:  Angle Orthod       Date:  1997       Impact factor: 2.079

6.  Nitinol arch wire in a simulated oral environment: changes in mechanical properties.

Authors:  E F Harris; S M Newman; J A Nicholson
Journal:  Am J Orthod Dentofacial Orthop       Date:  1988-06       Impact factor: 2.650

7.  The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics.

Authors:  F Miura; M Mogi; Y Ohura; H Hamanaka
Journal:  Am J Orthod Dentofacial Orthop       Date:  1986-07       Impact factor: 2.650

8.  An evaluation of 55 cobalt substituted Nitinol wire for use in orthodontics.

Authors:  G F Andreasen; T B Hilleman
Journal:  J Am Dent Assoc       Date:  1971-06       Impact factor: 3.634

9.  The bimetric system.

Authors:  F F Schudy; G F Schudy
Journal:  Am J Orthod       Date:  1975-01

10.  The ribbon arch. Its influence in the development of orthodontic appliances.

Authors:  B F Dewel
Journal:  Angle Orthod       Date:  1981-10       Impact factor: 2.079

View more