Literature DB >> 12567117

Influence of corneal variables on accuracy of intraocular pressure measurement.

Karim F Damji1, Rajeev H Muni, Rejean M Munger.   

Abstract

Mesh:

Year:  2003        PMID: 12567117     DOI: 10.1097/00061198-200302000-00015

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


× No keyword cloud information.
  25 in total

1.  Corneal displacement during tonometry with a noncontact tonometer.

Authors:  Yoshiaki Kiuchi; Makoto Kaneko; Hideki Mochizuki; Joji Takenaka; Kenji Yamada; Junko Tanaka
Journal:  Jpn J Ophthalmol       Date:  2012-03-27       Impact factor: 2.447

Review 2.  Biomechanics and wound healing in the cornea.

Authors:  William J Dupps; Steven E Wilson
Journal:  Exp Eye Res       Date:  2006-05-23       Impact factor: 3.467

3.  Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma.

Authors:  P Fogagnolo; L Rossetti; F Mazzolani; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

4.  Comparative analysis of biomechanically corrected intraocular pressure with corneal visualization Scheimpflug technology versus conventional noncontact intraocular pressure.

Authors:  Jiaonan Ma; Yan Wang; Weiting Hao; Vishal Jhanji
Journal:  Int Ophthalmol       Date:  2019-08-20       Impact factor: 2.031

5.  Limbal rebound tonometry: clinical comparisons and applications.

Authors:  Georgios Bontzos; Michail Agiorgiotakis; Zoi Kapsala; Efstathios Detorakis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-28       Impact factor: 3.117

6.  Intraocular Pressure Measurement Accuracy and Repeatability of a Modified Goldmann Prism: Multicenter Randomized Clinical Trial.

Authors:  Sean McCafferty; Kyle Tetrault; Ann McColgin; Warren Chue; Jason Levine; Melissa Muller
Journal:  Am J Ophthalmol       Date:  2018-09-07       Impact factor: 5.258

7.  Corneal hysteresis in patients with dry eye.

Authors:  P G Firat; S Doganay
Journal:  Eye (Lond)       Date:  2011-09-09       Impact factor: 3.775

8.  Differences in the early biomechanical effects of hyperopic and myopic laser in situ keratomileusis.

Authors:  Fabricio Witzel de Medeiros; Abhijit Sinha-Roy; Milton Ruiz Alves; Steven E Wilson; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2010-06       Impact factor: 3.351

9.  [Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].

Authors:  M Amm; J Hedderich
Journal:  Ophthalmologe       Date:  2005-01       Impact factor: 1.059

10.  Central corneal thickness and intraocular pressure in the Cameroonian nonglaucomatous population.

Authors:  André Omgbwa Eballe; Godefroy Koki; Augustin Ellong; Didier Owono; Emilienne Epée; Lucienne Assumpta Bella; Côme Ebana Mvogo; Jeanne Mayouego Kouam
Journal:  Clin Ophthalmol       Date:  2010-07-30
View more