Literature DB >> 12544075

Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography.

Stephan Achenbach1, Tom Giesler, Dieter Ropers, Stefan Ulzheimer, Katharina Anders, Evelyn Wenkel, Karsten Pohle, Marc Kachelriess, Hans Derlien, Willi A Kalender, Werner G Daniel, Werner Bautz, Ulrich Baum.   

Abstract

RATIONALE AND
OBJECTIVES: To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization.
MATERIALS AND METHODS: Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured.
RESULTS: Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P< 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P< 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography.
CONCLUSIONS: EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12544075     DOI: 10.1097/00004424-200302000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  26 in total

1.  The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.

Authors:  F Tatsugami; M Matsuki; G Nakai; Y Inada; S Kanazawa; Y Takeda; H Morita; H Takada; S Yoshikawa; K Fukumura; Y Narumi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

2.  Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model.

Authors:  B M Gramer; D Muenzel; V Leber; A-K von Thaden; H Feussner; A Schneider; M Vembar; N Soni; E J Rummeny; A M Huber
Journal:  Eur Radiol       Date:  2012-07-03       Impact factor: 5.315

3.  Non-invasive coronary angiography using multislice computed tomography.

Authors:  Jeffrey M Schussler; Paul A Grayburn
Journal:  Heart       Date:  2005-12-30       Impact factor: 5.994

4.  Detection of small vessels with electron beam computed tomographic angiography using 1.5 and 3 mm collimator protocols.

Authors:  Songshou Mao; Jerold S Shinbane; Ronald J Oudiz; Ferdinand Flores; Alex Chau; Stephen Liu; Shaojun Wang; Yanlin Gao; Matthew J Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2005-07-23       Impact factor: 2.357

5.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

6.  [Dual-source cardiac CT imaging with improved temporal resolution: Impact on image quality and analysis of left ventricular function].

Authors:  Carsten Rist; T R Johnson; A Becker; A W Leber; A Huber; S Busch; C R Becker; M F Reiser; K Nikolaou
Journal:  Radiologe       Date:  2007-04       Impact factor: 0.635

Review 7.  Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography.

Authors:  D Schnapauff; F Teige; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

8.  Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering.

Authors:  Bernhard A Herzog; Lars Husmann; Ines Valenta; Fabian M Tay; Nina Burkhard; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-19       Impact factor: 2.357

9.  Dual-source CT coronary imaging in heart transplant recipients: image quality and optimal reconstruction interval.

Authors:  Gorka Bastarrika; Carlo N De Cecco; Maria Arraiza; Matias Ubilla; Stefano Mastrobuoni; Jesús C Pueyo; Gregorio Rábago
Journal:  Eur Radiol       Date:  2008-04-17       Impact factor: 5.315

10.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.